Literature DB >> 17309902

Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure.

Dirk Vollmann1, Herbert Nägele, Patrick Schauerte, Uwe Wiegand, Christian Butter, Gabriele Zanotto, Aurelio Quesada, Axel Guthmann, Michael R S Hill, Barbara Lamp.   

Abstract

AIMS: To evaluate the utility of intrathoracic impedance monitoring for detecting heart failure (HF) deterioration in patients with an implanted cardiac resynchronization/defibrillation device. METHODS AND
RESULTS: Patients enrolled in the European InSync Sentry Observational Study were audibly alerted by a device algorithm if a decrease in intrathoracic impedance suggested fluid accumulation. Clinical HF status and device data were assessed at enrolment, during regular follow-up, and if patients presented with an alert or HF deterioration. Data from 373 subjects were analysed. Fifty-three alert events and a total of 53 clinical events (HF deterioration defined by worsening of HF signs and symptoms) were reported during a median of 4.2 months. Adjusted for multiple events per patient, the alert detected clinical HF deterioration with 60% sensitivity (95% CI 46-73) and with a positive predictive value of 60% (95% CI 46-73). Higher NYHA class at baseline was predictive for adequate alert events during follow-up (P < 0.05). In 11 of 20 HF deteriorations without preceding alert, an upstroke of the fluid index occurred without reaching the programmed alert threshold.
CONCLUSION: A device-based algorithm that alerts patients in case of decreasing intrathoracic impedance facilitates the detection of HF deterioration. Future randomized, controlled trials are needed to test whether the tailored use of intrathoracic impedance monitoring can improve the ambulatory management of patients with chronic HF and an implanted device.

Entities:  

Mesh:

Year:  2007        PMID: 17309902     DOI: 10.1093/eurheartj/ehl506

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  38 in total

1.  Intrathoracic impedance monitoring detecting pneumonia.

Authors:  Christine Barth; I Kindermann; F Mahfoud; A Buob; M Böhm
Journal:  Clin Res Cardiol       Date:  2010-02-18       Impact factor: 5.460

2.  Left ventricular epicardial admittance measurement for detection of acute LV dilation.

Authors:  John E Porterfield; Erik R Larson; James T Jenkins; Daniel Escobedo; Jonathan W Valvano; John A Pearce; Marc D Feldman
Journal:  J Appl Physiol (1985)       Date:  2010-12-09

Review 3.  Internet-based device-assisted remote monitoring of cardiovascular implantable electronic devices: an evidence-based analysis.

Authors:  G Pron; L Ieraci; K Kaulback
Journal:  Ont Health Technol Assess Ser       Date:  2012-01-01

Review 4.  Current Approach to Decongestive Therapy in Acute Heart Failure.

Authors:  Pieter Martens; Petra Nijst; Wilfried Mullens
Journal:  Curr Heart Fail Rep       Date:  2015-12

5.  Influence of lung volume, fluid and capillary recruitment during positional changes and exercise on thoracic impedance in heart failure.

Authors:  Chul-Ho Kim; Matthew A Fuglestad; Maile L Ceridon Richert; Win K Shen; Bruce D Johnson
Journal:  Respir Physiol Neurobiol       Date:  2014-08-14       Impact factor: 1.931

6.  Intracardiac impedance after cardiac resynchronization therapy is a novel predictor for worsening of heart failure.

Authors:  Hitoshi Suzuki; Minoru Nodera; Masashi Kamioka; Takashi Kaneshiro; Yoshiyuki Kamiyama; Yasuchika Takeishi
Journal:  Heart Vessels       Date:  2017-02-08       Impact factor: 2.037

Review 7.  Telemonitoring of left-ventricular assist device patients-current status and future challenges.

Authors:  Nils Reiss; Thomas Schmidt; Michael Boeckelmann; Sebastian Schulte-Eistrup; Jan-Dirk Hoffmann; Christina Feldmann; Jan D Schmitto
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

8.  Timing and duration of interventions in clinical trials for patients with hospitalized heart failure.

Authors:  Catherine N Marti; Gregg C Fonarow; Mihai Gheorghiade; Javed Butler
Journal:  Circ Heart Fail       Date:  2013-09-01       Impact factor: 8.790

9.  Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization.

Authors:  Giovanni B Perego; Maurizio Landolina; Giuseppe Vergara; Maurizio Lunati; Gabriele Zanotto; Alessia Pappone; Gabriele Lonardi; Giancarlo Speca; Saverio Iacopino; Annamaria Varbaro; Shantanu Sarkar; Doug A Hettrick; Alessandra Denaro
Journal:  J Interv Card Electrophysiol       Date:  2008-09-23       Impact factor: 1.900

10.  Design of the evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study to assess the ability of remote monitoring to treat and triage patients more effectively.

Authors:  Maurizio Marzegalli; Maurizio Landolina; Maurizio Lunati; Giovanni B Perego; Alessia Pappone; Giuseppe Guenzati; Carlo Campana; Maria Frigerio; Gianfranco Parati; Antonio Curnis; Irene Colangelo; Sergio Valsecchi
Journal:  Trials       Date:  2009-06-18       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.