Literature DB >> 18804770

Optimization of two-dimensional gradient liquid chromatography separations.

Petr Cesla1, Tomás Hájek, Pavel Jandera.   

Abstract

An almost orthogonal comprehensive two-dimensional liquid chromatography was developed for the separation of phenolic and flavone natural antioxidants by using combinations of a polyethylene glycol silica micro-column in the first dimension and a porous-shell fused-core C18 column in the second dimension, both in the reversed-phase mode. System orthogonality was improved using parallel gradients of acetonitrile in buffered mobile phase. A new approach was proposed to optimize matching segmented gradient profiles in the two dimensions. An algorithm was developed for automatic corrections of the shifts in retention in the second dimension induced by the parallel two-dimensional gradient operation technique. Using the porous-shell C18 column in the second dimension at elevated temperature (60 degrees C) and high pressure (480 bar) with optimized segmented profiles of the parallel gradients in the two dimensions, the overall separation time for comprehensive LC x LC was reduced to 30 min.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18804770     DOI: 10.1016/j.chroma.2008.08.111

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Effects of first dimension eluent composition in two-dimensional liquid chromatography.

Authors:  Xiaoping Li; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-02-16       Impact factor: 4.759

2.  Peak capacity optimization in comprehensive two dimensional liquid chromatography: a practical approach.

Authors:  Haiwei Gu; Yuan Huang; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-10-31       Impact factor: 4.759

3.  Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC×LC).

Authors:  Haiwei Gu; Yuan Huang; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-07-24       Impact factor: 4.759

4.  Development of a carbon clad core-shell silica for high speed two-dimensional liquid chromatography.

Authors:  Changyub Paek; Yuan Huang; Marcelo R Filgueira; Alon V McCormick; Peter W Carr
Journal:  J Chromatogr A       Date:  2012-01-11       Impact factor: 4.759

5.  A critical quality parameter in quantitative fused-core chromatography: The injection volume.

Authors:  Jente Boonen; Matthias D'hondt; Lieselotte Veryser; Kathelijne Peremans; Christian Burvenich; Bart De Spiegeleer
Journal:  J Pharm Anal       Date:  2013-02-17

Review 6.  Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications.

Authors:  Raffaella Preti
Journal:  Int J Anal Chem       Date:  2016-04-10       Impact factor: 1.885

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.