Literature DB >> 21143531

Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard.

Livia dos Santos Corpas1, Reinhilde Jacobs, Marc Quirynen, Yan Huang, Ignace Naert, Joke Duyck.   

Abstract

OBJECTIVES: The present study aims to identify radiographic methods revealing data that are most representative for the true peri-implant bone as assessed by histology.
MATERIALS AND METHODS: Eighty implants were placed in 10 minipigs. To assess matching between different image modalities, measurements conducted on intra-oral digital radiographs (IO), cone beam computer tomography (CBCT) and histological images were correlated using Spearman's correlation. Paired tests (Wilcoxon test) were used to determine changes in the bone parameters after 2 and 3 months of healing.
RESULTS: Significant correlations between bone defect depth on IO and histological slices (r= + 0.7, P<0.01), as well as on CBCT images and histological slices (r= + 0.61, P<0.01), were found. CBCT and IO images deviate, respectively, 1.20 and 1.17 mm from the histology regarding bone defects. No significant correlations were detected between fractal analysis on CBCT, intra-oral radiography and histology. For bone density assessment, significant but weaker correlations (r= + 0.5, P<0.01) were found for intra-oral radiography vs. histology. Significant marginal bone-level changes could be observed after 3 months of healing using intra-oral radiography.
CONCLUSIONS: This study allowed linking radiographic bone defect depth to the histological observations of the peri-implant bone. Minute bone changes during a short-term period can be followed up using digital intra-oral radiography. Radiographic fractal analysis did not seem to match histological fractal analysis. CBCT was not found to be reliable for bone density measures, but might hold potential with regard to the structural analysis of the trabecular bone.
© 2010 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21143531     DOI: 10.1111/j.1600-0501.2010.02029.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  25 in total

1.  Microcomputed tomography analysis of particular autogenous bone graft in sinus augmentation at 5 months: differences on bone mineral density and 3D trabecular structure.

Authors:  Heng-Li Huang; Jui-Ting Hsu; Michael Y C Chen; Cheng Liu; Ching-Han Chang; Yu-Fen Li; Kuan-Ting Chen
Journal:  Clin Oral Investig       Date:  2012-04-25       Impact factor: 3.573

2.  Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode.

Authors:  K Kamburoglu; E Kolsuz; S Murat; H Eren; S Yüksel; C S Paksoy
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013-10-16       Impact factor: 2.419

4.  Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study.

Authors:  Benjamin Salmon; Dominique Le Denmat
Journal:  Clin Oral Investig       Date:  2011-03-05       Impact factor: 3.573

5.  Evaluation of trabecular pattern of mandible using fractal dimension, bone area fraction, and gray scale value: comparison of cone-beam computed tomography and panoramic radiography.

Authors:  Guldane Magat; Sevgi Ozcan Sener
Journal:  Oral Radiol       Date:  2018-01-17       Impact factor: 1.852

6.  Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography.

Authors:  Dongyun Wang; Andreas Künzel; Vladimir Golubovic; Ilya Mihatovic; Gordon John; Zhuofan Chen; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2012-10-12       Impact factor: 3.573

Review 7.  Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

8.  Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view.

Authors:  K Kamburoğlu; S Murat; C Kılıç; S Yüksel; H Avsever; A Farman; W C Scarfe
Journal:  Dentomaxillofac Radiol       Date:  2014-03-20       Impact factor: 2.419

9.  Fractal analysis for the assessment of trabecular peri-implant alveolar bone using panoramic radiographs.

Authors:  Mert Zeytinoğlu; Betül İlhan; Nesrin Dündar; Hayal Boyacioğlu
Journal:  Clin Oral Investig       Date:  2014-05-07       Impact factor: 3.573

10.  Feasibility of cone beam computed tomography radiomorphometric analysis and fractal dimension in assessment of postmenopausal osteoporosis in correlation with dual X-ray absorptiometry.

Authors:  Raghdaa A Mostafa; Eman A Arnout; Mona M Abo El-Fotouh
Journal:  Dentomaxillofac Radiol       Date:  2016-08-02       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.