Literature DB >> 21138235

Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads.

A L Galvin1, L M Jennings, J L Tipper, E Ingham, J Fisher.   

Abstract

The wear and creep characteristics of highly crosslinked ultrahigh-molecular-weight polyethylene (UHMWPE) articulating against large-diameter (36mm) ceramic and cobalt chrome femoral heads have been investigated in a physiological anatomical hip joint simulator for 10 million cycles. The crosslinked UHMWPE/ceramic combination showed higher volume deformation due to creep plus wear during the first 2 million cycles, and a steady-state wear rate 40 per cent lower than that of the crosslinked UHMWPE/cobalt chrome combination. Wear particles were isolated and characterized from the hip simulator lubricants. The wear particles were similar in size and morphology for both head materials. The particle isolation methodology used could not detect a statistically significant difference between the particles produced by the cobalt chrome and alumina ceramic femoral heads.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21138235     DOI: 10.1243/09544119JEIM741

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

Review 1.  [Total hip arthroplasty in young patients : Bearings and custom-made prostheses].

Authors:  C Benignus; M Morlock; J Beckmann
Journal:  Orthopade       Date:  2019-04       Impact factor: 1.087

2.  How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  J Mater Sci Mater Med       Date:  2014-07-12       Impact factor: 3.896

3.  Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: a Retrieval Analysis.

Authors:  Chelsea N Koch; Mark Figgie; Mark P Figgie; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  HSS J       Date:  2017-06-22

4.  Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.

Authors:  Murat Ali; Mazen Al-Hajjar; Susan Partridge; Sophie Williams; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-05       Impact factor: 1.617

5.  The increase in cobalt release in metal-on-polyethylene hip bearings in tests with third body abrasives.

Authors:  Danielle de Villiers; Alison Traynor; Simon N Collins; Julia C Shelton
Journal:  Proc Inst Mech Eng H       Date:  2015-07-15       Impact factor: 1.617

6.  Prospective Study Showing Results of Large-Diameter Femoral Heads After Cementless Total Hip Replacement.

Authors:  Gur Aziz Singh Sidhu; Harjot Kaur; Hakam Singh; Jamie Hind; Neil Ashwood
Journal:  Cureus       Date:  2021-01-10

7.  (iv) Enhancing the safety and reliability of joint replacement implants.

Authors:  Louise M Jennings; Mazen Al-Hajjar; Claire L Brockett; Sophie Williams; Joanne L Tipper; Eileen Ingham; John Fisher
Journal:  Orthop Trauma       Date:  2012-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.