Literature DB >> 21122863

Characterization of blood clot viscoelasticity by dynamic ultrasound elastography and modeling of the rheological behavior.

Cédric Schmitt1, Anis Hadj Henni, Guy Cloutier.   

Abstract

Dynamic elastography (DE) is a new tool to study mechanical behavior of soft tissues via their motion response to propagating shear waves. This technique characterized viscoelasticity of 9 porcine whole blood samples (3 animals) during coagulation for a shearing frequency of 70Hz, and after complete clot formation between 50 and 160Hz. Clot storage (G') and loss (G″) moduli were calculated from shear wave velocity and attenuation. Temporal evolutions of G' and G″ during coagulation were typified with 4 parameters: maximum change in elasticity (G' slope(max)), elasticity after 120min of coagulation (G'(max)), time occurrence of G″ maximum (t(e)) and G″ at the plateau (G″(plateau)). G' and G″ frequency dependence of completely formed blood clots was fitted with 5 standard rheological models: Maxwell, Kelvin-Voigt, Jeffrey, Zener and third-order generalized Maxwell. DE had sufficient sensitivity to follow the coagulation kinetics described by a progressive increase in G', while G″ transitory increased followed by a rapid stabilization. Inter- and intra-animal dispersions (InterAD and IntraAD) of G'(max) (InterAD=15.9%, IntraAD=9.1%) showed better reproducibility than G' slope(max) (InterAD=40.4%, IntraAD=21.9%), t(e) (InterAD=27.4%, IntraAD=18.7%) and G″(plateau) (InterAD=58.6%, IntraAD=40.2%). G' evolution within the considered range of frequency exhibited an increase, followed by stabilization to a plateau, whereas G″ presented little variations with convergence at a quasi-constant value at highest frequencies. Residues χ(⁎), describing the goodness of fit between models and experimental data, showed statistically (p<0.05) that the Kelvin-Voigt model was less in agreement with experimental data than other models. The Zener model is recommended to predict G' and G″ dispersion of coagulated blood over the explored frequency range.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2010        PMID: 21122863     DOI: 10.1016/j.jbiomech.2010.11.015

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  A mathematical model for analyzing the elasticity, viscosity, and failure of soft tissue: comparison of native and decellularized porcine cardiac extracellular matrix for tissue engineering.

Authors:  Tomer Bronshtein; Gigi Chi Ting Au-Yeung; Udi Sarig; Evelyne Bao-Vi Nguyen; Priyadarshini S Mhaisalkar; Freddy Yin Chiang Boey; Subbu S Venkatraman; Marcelle Machluf
Journal:  Tissue Eng Part C Methods       Date:  2013-04-05       Impact factor: 3.056

2.  Sonic Estimation of Elasticity via Resonance: A New Method of Assessing Hemostasis.

Authors:  F Scott Corey; William F Walker
Journal:  Ann Biomed Eng       Date:  2015-09-23       Impact factor: 3.934

3.  Non-contact, ultrasound-based indentation method for measuring elastic properties of biological tissues using harmonic motion imaging (HMI).

Authors:  Jonathan Vappou; Gary Y Hou; Fabrice Marquet; Danial Shahmirzadi; Julien Grondin; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2015-03-17       Impact factor: 3.609

4.  Assessing composition and structure of soft biphasic media from Kelvin-Voigt fractional derivative model parameters.

Authors:  Hong Mei Zhang; Yue Wang; Mostafa Fatemi; Michael F Insana
Journal:  Meas Sci Technol       Date:  2017-01-17       Impact factor: 2.046

5.  A Fluid-Structure Interaction Analysis of Blood Clot Motion in a Branch of Pulmonary Arteries.

Authors:  Fateme Mirakhorli; Bahman Vahidi; Marzieh Pazouki; Pouria Talebi Barmi
Journal:  Cardiovasc Eng Technol       Date:  2022-07-05       Impact factor: 2.495

6.  The influence of medium elasticity on the prediction of histotripsy-induced bubble expansion and erythrocyte viability.

Authors:  Kenneth B Bader
Journal:  Phys Med Biol       Date:  2018-05-02       Impact factor: 3.609

7.  Scattering and Diffraction of Elastodynamic Waves in a Concentric Cylindrical Phantom for MR Elastography.

Authors:  Benjamin L Schwartz; Ziying Yin; Temel K Yasar; Yifei Liu; Altaf A Khan; Allen Q Ye; Thomas J Royston; Richard L Magin
Journal:  IEEE Trans Biomed Eng       Date:  2016-02-11       Impact factor: 4.538

8.  Multimode ultrasound viscoelastography for three-dimensional interrogation of microscale mechanical properties in heterogeneous biomaterials.

Authors:  Xiaowei Hong; Ramkumar T Annamalai; Tyler S Kemerer; Cheri X Deng; Jan P Stegemann
Journal:  Biomaterials       Date:  2018-06-02       Impact factor: 12.479

9.  Characterizing blood clots using acoustic radiation force optical coherence elastography and ultrasound shear wave elastography.

Authors:  Hsiao-Chuan Liu; Mehdi Abbasi; Yong Hong Ding; Tuhin Roy; Margherita Capriotti; Yang Liu; Seán Fitzgerald; Karen M Doyle; Murthy Guddati; Matthew W Urban; Waleed Brinjikji
Journal:  Phys Med Biol       Date:  2021-01-26       Impact factor: 3.609

10.  Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters.

Authors:  Ronald A Robinson; Luke H Herbertson; Srilekha Sarkar Das; Richard A Malinauskas; William F Pritchard; Laurence W Grossman
Journal:  Med Devices (Auckl)       Date:  2013-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.