Literature DB >> 26399992

Sonic Estimation of Elasticity via Resonance: A New Method of Assessing Hemostasis.

F Scott Corey1, William F Walker2,3.   

Abstract

Uncontrolled bleeding threatens patients undergoing major surgery and in care for traumatic injury. This paper describes a novel method of diagnosing coagulation dysfunction by repeatedly measuring the shear modulus of a blood sample as it clots in vitro. Each measurement applies a high-energy ultrasound pulse to induce a shear wave within a rigid walled chamber, and then uses low energy ultrasound pulses to measure displacements associated with the resonance of that shear wave. Measured displacements are correlated with predictions from finite difference time domain models, with the best fit corresponding to the modulus estimate. In our current implementation each measurement requires 62.4 ms. Experimental data was analyzed using a fixed-viscosity algorithm and a free-viscosity algorithm. In experiments utilizing human blood induced to clot by exposure to kaolin, the free-viscosity algorithm quantified the shear modulus of formed clots with a worst-case precision of 2.5%. Precision was improved to 1.8% by utilizing the fixed-viscosity algorithm. Repeated measurements showed a smooth evolution from liquid blood to a firm clot with a shear modulus between 1.4 and 3.3 kPa. These results show the promise of this technique for rapid, point of care assessment of coagulation.

Entities:  

Keywords:  Coagulation; FDTD; Resonance; Shear modulus; Shear waves; Ultrasound

Mesh:

Year:  2015        PMID: 26399992      PMCID: PMC4805516          DOI: 10.1007/s10439-015-1460-y

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  26 in total

1.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Authors:  A P Sarvazyan; O V Rudenko; S D Swanson; J B Fowlkes; S Y Emelianov
Journal:  Ultrasound Med Biol       Date:  1998-11       Impact factor: 2.998

2.  A comparison of the performance of time-delay estimators in medical ultrasound.

Authors:  Francesco Viola; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-04       Impact factor: 2.725

3.  Multi-centre investigation on reference ranges for ROTEM thromboelastometry.

Authors:  Thomas Lang; Anne Bauters; Siegmund L Braun; Bernd Pötzsch; Klaus-Werner von Pape; Hans-Jürgen Kolde; Meret Lakner
Journal:  Blood Coagul Fibrinolysis       Date:  2005-06       Impact factor: 1.276

4.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

5.  Estimating the viscoelastic modulus of a thrombus using an ultrasonic shear-wave approach.

Authors:  Chih-Chung Huang; Pay-Yu Chen; Cho-Chiang Shih
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

Review 6.  The coagulopathy of trauma versus disseminated intravascular coagulation.

Authors:  John R Hess; Jeffrey H Lawson
Journal:  J Trauma       Date:  2006-06

Review 7.  The bidirectional relationship of cancer and hemostasis and the potential role of anticoagulant therapy in moderating thrombosis and cancer spread.

Authors:  Massimo Franchini; Martina Montagnana; Emmanuel J Favaloro; Giuseppe Lippi
Journal:  Semin Thromb Hemost       Date:  2009-10       Impact factor: 4.180

8.  Normal range values for thromboelastography in healthy adult volunteers.

Authors:  S Scarpelini; S G Rhind; B Nascimento; H Tien; P N Shek; H T Peng; H Huang; R Pinto; V Speers; M Reis; S B Rizoli
Journal:  Braz J Med Biol Res       Date:  2009-10-30       Impact factor: 2.590

9.  Adaptive force sonorheometry for assessment of whole blood coagulation.

Authors:  F William Mauldin; Francesco Viola; Theresa C Hamer; Eman M Ahmed; Shawna B Crawford; Doris M Haverstick; Michael B Lawrence; William F Walker
Journal:  Clin Chim Acta       Date:  2010-01-22       Impact factor: 3.786

10.  Comparison of fibrin-based clot elasticity parameters measured by free oscillation rheometry (ReoRox ®) versus thromboelastometry (ROTEM ®).

Authors:  Cristina Solomon; Herbert Schöchl; Marco Ranucci; Ulf Schött; Christoph J Schlimp
Journal:  Scand J Clin Lab Invest       Date:  2015-01-19       Impact factor: 1.713

View more
  8 in total

1.  Efficacy of sonorheometry point of the care device in determining low fibrinogen levels in pregnant blood: an invitro dilution and reconstitution study.

Authors:  Bhavani Shankar Kodali; Arun Karuppiah; Shobana Bharadwaj; Jonathan Chow; Kenichi Tanaka
Journal:  J Clin Monit Comput       Date:  2021-12-03       Impact factor: 1.977

Review 2.  Production of acoustic radiation force using ultrasound: methods and applications.

Authors:  Matthew W Urban
Journal:  Expert Rev Med Devices       Date:  2018-10-31       Impact factor: 3.166

3.  A Novel Device for the Evaluation of Hemostatic Function in Critical Care Settings.

Authors:  Elisa A Ferrante; Kiev R Blasier; Thomas B Givens; Cynthia A Lloyd; Timothy J Fischer; Francesco Viola
Journal:  Anesth Analg       Date:  2016-12       Impact factor: 5.108

4.  Resonant acoustic rheometry for non-contact characterization of viscoelastic biomaterials.

Authors:  Eric C Hobson; Weiping Li; Benjamin A Juliar; Andrew J Putnam; Jan P Stegemann; Cheri X Deng
Journal:  Biomaterials       Date:  2021-01-15       Impact factor: 12.479

Review 5.  Hemostatic Testing in Critically Ill Infants and Children.

Authors:  Alison B Nair; Robert I Parker
Journal:  Front Pediatr       Date:  2021-01-08       Impact factor: 3.418

6.  Comparison of the resonance sonorheometry based Quantra® system with rotational thromboelastometry ROTEM® sigma in cardiac surgery - a prospective observational study.

Authors:  Werner Baulig; Samira Akbas; Michael Thomas Ganter; Oliver M Theusinger; Philipp K Schütt; Wolfgang Keul; Marija Jovic; Pascal Berdat; Stefanie von Felten; Klaus Steigmiller
Journal:  BMC Anesthesiol       Date:  2021-10-28       Impact factor: 2.217

Review 7.  Questions about COVID-19 associated coagulopathy: possible answers from the viscoelastic tests.

Authors:  Vittorio Pavoni; Lara Gianesello; Maddalena Pazzi; Pietro Dattolo; Domenico Prisco
Journal:  J Clin Monit Comput       Date:  2021-07-15       Impact factor: 1.977

8.  Comparison of Coagulation Parameters in Arterial and Venous Blood in Cardiac Surgery Measured Using the Quantra System.

Authors:  Danja S Groves; Deborah A Winegar; Lucas G Fernandez; Julie L Huffmyer; Francesco Viola
Journal:  J Cardiothorac Vasc Anesth       Date:  2018-08-31       Impact factor: 2.628

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.