Analysis of output trends from Varian 2100C/D and 600C/D accelerators.

M W D Grattan1, A R Hounsell.   

Abstract

Analysis of Varian linear accelerator output trends is reported. Two groups, consisting of four matched Varian 2100C/D and four matched Varian 600C/D accelerators, with different designs of monitor chamber, have been investigated and the data acquired from regular calibrated ion chamber/electrometer measurements of the output performance of the eight accelerators analysed. The trend of machine output with time, having removed the effect of adjusting the monitor chamber response, was compared on a monthly and annual basis for monitor chambers with ages ranging between 1 year and 7 years. The results indicate that the response is generally consistent within each set of accelerators with different monitor chamber designs. Those used in a Varian 600C/D machine result in a reduction in measured output over time, with an average monthly reduction of 0.35 ± 0.09% over the course of the first 4 years of use. The chambers used in a 2100C/D accelerator result in an increase in measured output over time, with an average monthly increase of 0.26 ± 0.09% over the course of the first 4 years of use. The output increase then reduces towards the end of this period of time, with the average monthly change falling to -0.03 ± 0.02% for the following 3 years. The output response trend was similar for all clinical energies used on the 2100C/D accelerators--6, 15 MV x-ray beams, and 4, 6, 9, 12, 16 and 20 MeV electron beams. By tracking these changes it has been possible to predict the response over time to allow appropriate adjustments in monitor chamber response to maintain a measured accelerator output within tolerance and give confidence in performance. It has also provided data to indicate the need for planned preventative intervention and indicate if the monitor chamber response is behaving as expected.

Mesh:

Year:  2010        PMID: 21119232     DOI: 10.1088/0031-9155/56/1/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Predictive time-series modeling using artificial neural networks for Linac beam symmetry: an empirical study.

Authors:  Qiongge Li; Maria F Chan
Journal:  Ann N Y Acad Sci       Date:  2016-09-14       Impact factor: 5.691

2.  Diagnosing atmospheric communication of a sealed monitor chamber.

Authors:  Travis J McCaw; Brendan A Barraclough; Maxwell Belanger; Abigail Besemer; David A P Dunkerley; Zacariah E Labby
Journal:  J Appl Clin Med Phys       Date:  2020-07-10       Impact factor: 2.102

3.  The lifetime of a linac monitor unit ion chamber.

Authors:  Ashley J Cetnar; Dominic J DiCostanzo
Journal:  J Appl Clin Med Phys       Date:  2021-11-11       Impact factor: 2.102

4.  Output trends, characteristics, and measurements of three megavoltage radiotherapy linear accelerators.

Authors:  Murshed Hossain
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

5.  Visual Analysis of the Daily QA Results of Photon and Electron Beams of a Trilogy Linac over a Five-year Period.

Authors:  Maria F Chan; Qiongge Li; Xiaoli Tang; Xiang Li; Jingdong Li; Grace Tang; Margie A Hunt; Joseph O Deasy
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2015-11-09

6.  Retrospective analysis of linear accelerator output constancy checks using process control techniques.

Authors:  Taweap Sanghangthum; Sivalee Suriyapee; Somyot Srisatit; Todd Pawlicki
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

7.  Long-term experience of MPC across multiple TrueBeam linacs: MPC concordance with conventional QC and sensitivity to real-world faults.

Authors:  Michael Pearson; David Eaton; Tony Greener
Journal:  J Appl Clin Med Phys       Date:  2020-08-13       Impact factor: 2.102

8.  Quantification of the uncertainties within the radiotherapy dosimetry chain and their impact on tumour control.

Authors:  Matthew Bolt; Catharine H Clark; Andrew Nisbet; Tao Chen
Journal:  Phys Imaging Radiat Oncol       Date:  2021-06-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.