PET energy-based scatter estimation and image reconstruction with energy-dependent corrections.

Lucreţiu M Popescu1, Robert M Lewitt, Samuel Matej, Joel S Karp.   

Abstract

In this paper we propose a comprehensive energy-based scatter correction approach for positron emission tomography (PET). We take advantage of the marked difference between the energy spectra of the unscattered and scattered photons, and use the detailed energy information that comes with the list-mode data for the estimation of the scattered events distribution in the data space. Also, inside the maximum-likelihood expectation maximization (ML-EM) image reconstruction algorithm, we introduce energy-dependent factors that individualize the correction terms for each event, given its position and energy information. The central piece of our approach is the two-dimensional detector energy response model represented as a linear combination of four components, each one representing a particular state a PET event can be found in: both photons unscattered, the second scattered while the first not, the first photon scattered while the second not and both photons scattered. For a set of events collected in the vicinity of a point in the projection space, the coefficient of each component is determined by applying a statistical estimator. As a result we obtain the number of scattered events that are in the given set. The model also gives us the variation of scatter fraction with the photon pair energies for that particular position in the data space. A simulation study that demonstrates the proposed methods is presented.

Mesh:

Year:  2006        PMID: 16723775     DOI: 10.1088/0031-9155/51/11/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  A method for measuring the energy spectrum of coincidence events in positron emission tomography.

Authors:  Andrew L Goertzen; David B Stout; Christopher J Thompson
Journal:  Phys Med Biol       Date:  2009-12-21       Impact factor: 3.609

3.  Novel scatter compensation of list-mode PET data using spatial and energy dependent corrections.

Authors:  Bastien Guérin; Georges El Fakhri
Journal:  IEEE Trans Med Imaging       Date:  2010-11-29       Impact factor: 10.048

4.  Data-driven, energy-based method for estimation of scattered events in positron emission tomography.

Authors:  Nikos Efthimiou; Joel S Karp; Suleman Surti
Journal:  Phys Med Biol       Date:  2022-04-21       Impact factor: 4.174

5.  A LIST-MODE OSEM-BASED ATTENUATION AND SCATTER COMPENSATION METHOD FOR SPECT.

Authors:  Md Ashequr Rahman; Richard Laforest; Abhinav K Jha
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2020-05-22

Review 6.  PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques.

Authors:  Joseph Lillington; Ludovica Brusaferri; Kerstin Kläser; Karin Shmueli; Radhouene Neji; Brian F Hutton; Francesco Fraioli; Simon Arridge; Manuel Jorge Cardoso; Sebastien Ourselin; Kris Thielemans; David Atkinson
Journal:  Med Phys       Date:  2020-01-01       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.