Abstract

PURPOSE: The aim of this study was to evaluate the efficacy of a computer-aided diagnosis (CAD) system we developed that can also respond to subsolid nodules, for lung cancer screening using low-dose spiral computed tomography (LDCT).
MATERIALS AND METHODS: The institutional review board approved this study. A total of 30 positive cases (including 15 lung cancer cases) that needed further examination and 30 negative cases were used for the observer performance study. Three thoracic radiologists, five general radiologists, and three residents participated in this study in which they first read the original CT image on its own and then reassessed the same image with the assistance of CAD. Radiologists' performance was evaluated using receiver operating characteristic (ROC) analysis.
RESULTS: The Az values without and with CAD were 0.872 and 0.910 for the thoracic radiologists, 0.864 and 0.924 for general radiologists, and 0.875 and 0.837 for residents, respectively. The detection accuracy improved significantly for the thoracic and general radiologists with our CAD system; however, no statistically significant difference between without or with CAD was seen for residents.
CONCLUSION: This CAD system is beneficial in the detection of pulmonary nodules on LDCT when used by experienced radiologists.

Entities:  

Mesh:

Year:  2010        PMID: 21113748     DOI: 10.1007/s11604-010-0486-1

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  27 in total

1.  Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program.

Authors:  Samuel G Armato; Feng Li; Maryellen L Giger; Heber MacMahon; Shusuke Sone; Kunio Doi
Journal:  Radiology       Date:  2002-12       Impact factor: 11.105

2.  Computer-aided diagnosis to distinguish benign from malignant solitary pulmonary nodules on radiographs: ROC analysis of radiologists' performance--initial experience.

Authors:  Junji Shiraishi; Hiroyuki Abe; Roger Engelmann; Masahito Aoyama; Heber MacMahon; Kunio Doi
Journal:  Radiology       Date:  2003-05       Impact factor: 11.105

3.  Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists' detection performance.

Authors:  Kazuo Awai; Kohei Murao; Akio Ozawa; Masanori Komi; Haruo Hayakawa; Shinichi Hori; Yasumasa Nishimura
Journal:  Radiology       Date:  2004-02       Impact factor: 11.105

4.  Estimating long-term effectiveness of lung cancer screening in the Mayo CT screening study.

Authors:  Pamela M McMahon; Chung Yin Kong; Bruce E Johnson; Milton C Weinstein; Jane C Weeks; Karen M Kuntz; Jo-Anne O Shepard; Stephen J Swensen; G Scott Gazelle
Journal:  Radiology       Date:  2008-05-05       Impact factor: 11.105

5.  Early Lung Cancer Action Project: overall design and findings from baseline screening.

Authors:  C I Henschke; D I McCauley; D F Yankelevitz; D P Naidich; G McGuinness; O S Miettinen; D M Libby; M W Pasmantier; J Koizumi; N K Altorki; J P Smith
Journal:  Lancet       Date:  1999-07-10       Impact factor: 79.321

6.  Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers.

Authors:  Stefan Diederich; Dag Wormanns; Michael Semik; Michael Thomas; Horst Lenzen; Nikolaus Roos; Walter Heindel
Journal:  Radiology       Date:  2002-03       Impact factor: 11.105

7.  Computer-aided detection in computed tomography colonography: current status and problems with detection of early colorectal cancer.

Authors:  Tsuyoshi Morimoto; Gen Iinuma; Junji Shiraishi; Yasuaki Arai; Noriyuki Moriyama; Gareth Beddoe; Yasuo Nakijima
Journal:  Radiat Med       Date:  2008-07-27

8.  Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.

Authors:  M Kaneko; K Eguchi; H Ohmatsu; R Kakinuma; T Naruke; K Suemasu; N Moriyama
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

9.  Early lung cancer detection: results of the initial (prevalence) radiologic and cytologic screening in the Memorial Sloan-Kettering study.

Authors:  B J Flehinger; M R Melamed; M B Zaman; R T Heelan; W B Perchick; N Martini
Journal:  Am Rev Respir Dis       Date:  1984-10

10.  Results of three-year mass screening programme for lung cancer using mobile low-dose spiral computed tomography scanner.

Authors:  S Sone; F Li; Z G Yang; T Honda; Y Maruyama; S Takashima; M Hasegawa; S Kawakami; K Kubo; M Haniuda; T Yamanda
Journal:  Br J Cancer       Date:  2001-01-05       Impact factor: 7.640

View more
  3 in total

Review 1.  After Detection: The Improved Accuracy of Lung Cancer Assessment Using Radiologic Computer-aided Diagnosis.

Authors:  Guy J Amir; Harold P Lehmann
Journal:  Acad Radiol       Date:  2015-11-23       Impact factor: 3.173

2.  An Official American Thoracic Society Research Statement: A Research Framework for Pulmonary Nodule Evaluation and Management.

Authors:  Christopher G Slatore; Nanda Horeweg; James R Jett; David E Midthun; Charles A Powell; Renda Soylemez Wiener; Juan P Wisnivesky; Michael K Gould
Journal:  Am J Respir Crit Care Med       Date:  2015-08-15       Impact factor: 21.405

3.  Comparison of sensitivity of lung nodule detection between radiologists and technologists on low-dose CT lung cancer screening images.

Authors:  R Kakinuma; K Ashizawa; T Kobayashi; A Fukushima; H Hayashi; T Kondo; M Machida; M Matsusako; K Minami; K Oikado; M Okuda; S Takamatsu; M Sugawara; S Gomi; Y Muramatsu; K Hanai; Y Muramatsu; M Kaneko; R Tsuchiya; N Moriyama
Journal:  Br J Radiol       Date:  2012-09       Impact factor: 3.039

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.