Literature DB >> 21097372

B-scan based acoustic source reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI).

Leo Mariappan1, Xu Li, Bin He.   

Abstract

We present in this study, an acoustic source reconstruction method using focused transducer with B-mode imaging for magnetoacoustic tomography with magnetic induction (MAT-MI). MAT-MI is an imaging modality proposed for noninvasive conductivity imaging with high spatial resolution. In MAT-MI, acoustic sources are generated in a conductive object by placing it in a static and a time-varying magnetic field. The acoustic waves from these sources propagate in all directions and are collected with transducers placed around the object. The collected signal is then used to reconstruct the acoustic source distribution and to further estimate the electrical conductivity distribution of the object. A flat piston transducer acting as a point receiver has been used in earlier MAT-MI systems to collect acoustic signals. In this study, we propose to use B-mode scan scheme with a focused transducer that gives a signal gain in its focus region and improves the MAT-MI signal quality. A simulation protocol that can take into account different transducer designs and scan schemes for MAT-MI imaging is developed and used in our evaluation of different MAT-MI system designs. It is shown in our computer simulations that as compared to the earlier approach, the MAT-MI system using B-scan with a focused transducer allows MAT-MI imaging at a closer distance and has improved system sensitivity. In addition, the B-scan imaging technique allows reconstruction of the MAT-MI acoustic sources with a discrete number of scanning locations, which greatly increases the applicability of the MAT-MI approach, especially when a continuous acoustic window is not available in real clinical applications. We have also conducted phantom experiments to evaluate the proposed method, and the reconstructed image shows a good agreement with the target phantom.

Entities:  

Mesh:

Year:  2010        PMID: 21097372      PMCID: PMC3044776          DOI: 10.1109/TBME.2010.2094618

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  25 in total

1.  Microwave-induced thermoacoustic tomography using multi-sector scanning.

Authors:  M Xu; G Ku; L V Wang
Journal:  Med Phys       Date:  2001-09       Impact factor: 4.071

2.  Reconstructions in limited-view thermoacoustic tomography.

Authors:  Yuan Xu; Lihong V Wang; Gaik Ambartsoumian; Peter Kuchment
Journal:  Med Phys       Date:  2004-04       Impact factor: 4.071

3.  Optoacoustic imaging with synthetic aperture focusing and coherence weighting.

Authors:  C K Liao; M L Li; P C Li
Journal:  Opt Lett       Date:  2004-11-01       Impact factor: 3.776

4.  Estimation of electrical conductivity distribution within the human head from magnetic flux density measurement.

Authors:  Nuo Gao; S A Zhu; Bin He
Journal:  Phys Med Biol       Date:  2005-05-18       Impact factor: 3.609

5.  Magnetoacoustic tomography with magnetic induction (MAT-MI).

Authors:  Yuan Xu; Bin He
Journal:  Phys Med Biol       Date:  2005-10-19       Impact factor: 3.609

6.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

7.  The effect of electrical anisotropy during magnetoacoustic tomography with magnetic induction.

Authors:  Kaytlin Brinker; Bradley J Roth
Journal:  IEEE Trans Biomed Eng       Date:  2008-05       Impact factor: 4.538

8.  Hall effect imaging.

Authors:  H Wen; J Shah; R S Balaban
Journal:  IEEE Trans Biomed Eng       Date:  1998-01       Impact factor: 4.538

9.  Negative lens concept for photoacoustic tomography.

Authors:  Changhui Li; Geng Ku; Lihong V Wang
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2008-08-06

10.  Solving the forward problem of magnetoacoustic tomography with magnetic induction by means of the finite element method.

Authors:  Xun Li; Xu Li; Shanan Zhu; Bin He
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

View more
  12 in total

1.  A reconstruction algorithm of magnetoacoustic tomography with magnetic induction for an acoustically inhomogeneous tissue.

Authors:  Lian Zhou; Shanan Zhu; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2014-06       Impact factor: 4.538

2.  Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet.

Authors:  Leo Mariappan; Gang Hu; Bin He
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

3.  Determining electrical properties based on B(1) fields measured in an MR scanner using a multi-channel transmit/receive coil: a general approach.

Authors:  Jiaen Liu; Xiaotong Zhang; Pierre-Francois Van de Moortele; Sebastian Schmitter; Bin He
Journal:  Phys Med Biol       Date:  2013-06-06       Impact factor: 3.609

4.  In Vivo Electrical Conductivity Contrast Imaging in a Mouse Model of Cancer Using High-Frequency Magnetoacoustic Tomography With Magnetic Induction (hfMAT-MI).

Authors:  Shai Ashkenazi; John C Bischof
Journal:  IEEE Trans Med Imaging       Date:  2016-10       Impact factor: 10.048

5.  Magnetoacoustic tomography with magnetic induction: bioimepedance reconstruction through vector source imaging.

Authors:  Leo Mariappan; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2013-01-11       Impact factor: 10.048

Review 6.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

Review 7.  Magnetoacoustic tomography with magnetic induction (MAT-MI) for imaging electrical conductivity of biological tissue: a tutorial review.

Authors:  Xu Li; Kai Yu; Bin He
Journal:  Phys Med Biol       Date:  2016-08-19       Impact factor: 3.609

8.  From complex B(1) mapping to local SAR estimation for human brain MR imaging using multi-channel transceiver coil at 7T.

Authors:  Xiaotong Zhang; Sebastian Schmitter; Pierre-Francois Van de Moortele; Jiaen Liu; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2013-03-11       Impact factor: 10.048

9.  Magneto acoustic tomography with short pulsed magnetic field for in-vivo imaging of magnetic iron oxide nanoparticles.

Authors:  Leo Mariappan; Qi Shao; Chunlan Jiang; Kai Yu; Shai Ashkenazi; John C Bischof; Bin He
Journal:  Nanomedicine       Date:  2015-12-02       Impact factor: 5.307

10.  Numerical study of magnetoacoustic signal generation with magnetic induction based on inhomogeneous conductivity anisotropy.

Authors:  Xun Li; Sanqing Hu; Lihua Li; Shanan Zhu
Journal:  Comput Math Methods Med       Date:  2013-03-26       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.