Literature DB >> 15901962

Estimation of electrical conductivity distribution within the human head from magnetic flux density measurement.

Nuo Gao1, S A Zhu, Bin He.   

Abstract

We have developed a new algorithm for magnetic resonance electrical impedance tomography (MREIT), which uses only one component of the magnetic flux density to reconstruct the electrical conductivity distribution within the body. The radial basis function (RBF) network and simplex method are used in the present approach to estimate the conductivity distribution by minimizing the errors between the 'measured' and model-predicted magnetic flux densities. Computer simulations were conducted in a realistic-geometry head model to test the feasibility of the proposed approach. Single-variable and three-variable simulations were performed to estimate the brain-skull conductivity ratio and the conductivity values of the brain, skull and scalp layers. When SNR = 15 for magnetic flux density measurements with the target skull-to-brain conductivity ratio being 1/15, the relative error (RE) between the target and estimated conductivity was 0.0737 +/- 0.0746 in the single-variable simulations. In the three-variable simulations, the RE was 0.1676 +/- 0.0317. Effects of electrode position uncertainty were also assessed by computer simulations. The present promising results suggest the feasibility of estimating important conductivity values within the head from noninvasive magnetic flux density measurements.

Entities:  

Mesh:

Year:  2005        PMID: 15901962     DOI: 10.1088/0031-9155/50/11/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  High field MREIT: setup and tissue phantom imaging at 11 T.

Authors:  Rosalind Sadleir; Samuel Grant; Sung Uk Zhang; Suk Hoon Oh; Byung Il Lee; Eung Je Woo
Journal:  Physiol Meas       Date:  2006-04-24       Impact factor: 2.833

2.  Magnetoacoustic tomography with magnetic induction (MAT-MI).

Authors:  Yuan Xu; Bin He
Journal:  Phys Med Biol       Date:  2005-10-19       Impact factor: 3.609

3.  A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity.

Authors:  Nuo Gao; S A Zhu; Bin He
Journal:  Phys Med Biol       Date:  2006-05-31       Impact factor: 3.609

4.  B-scan based acoustic source reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI).

Authors:  Leo Mariappan; Xu Li; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2010-11-22       Impact factor: 4.538

5.  A Phantom Study of Magnetoacoustic Tomography with Magnetic Induction (MAT-MI) for Imaging Electrical Impedance of Biological Tissue.

Authors:  Xu Li; Yuan Xu; Bin He
Journal:  J Appl Phys       Date:  2006-03-29       Impact factor: 2.546

6.  A reconstruction algorithm of magnetoacoustic tomography with magnetic induction for an acoustically inhomogeneous tissue.

Authors:  Lian Zhou; Shanan Zhu; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2014-06       Impact factor: 4.538

7.  Brain Tissue Conductivity Measurements with MR-Electrical Properties Tomography: An In Vivo Study.

Authors:  Stefano Mandija; Petar I Petrov; Jord J T Vink; Sebastian F W Neggers; Cornelis A T van den Berg
Journal:  Brain Topogr       Date:  2020-12-08       Impact factor: 3.020

Review 8.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

9.  Solving the forward problem of magnetoacoustic tomography with magnetic induction by means of the finite element method.

Authors:  Xun Li; Xu Li; Shanan Zhu; Bin He
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

10.  Noninvasive imaging of head-brain conductivity profiles.

Authors:  Xiaotong Zhang; Dandan Yan; Shanan Zhu; Bin He
Journal:  IEEE Eng Med Biol Mag       Date:  2008 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.