Literature DB >> 21093388

High performance liquid chromatography assay with ultraviolet detection for moxifloxacin: validation and application to a pharmacokinetic study in Chinese volunteers.

Yu Hong Xu1, Dong Li, Xin Yu Liu, Yu Zhen Li, Jian Lu.   

Abstract

A specific, sensitive and widely applicable high performance liquid chromatography with ultraviolet detection (HPLC-UV) method for the determination of moxifloxacin in human plasma was developed and validated in this study. The method involved a single step of liquid-liquid extraction with dichloromethane and the extraction yields more than 80% were achieved. The separation was performed on a common Kromasil C(8) column with an isocratic mobile phase. The total time was within 10 min per run. The calibration curve for moxifloxacin was linear in the concentration range of 0.05-5.0 μg/ml with correlation coefficient of 0.9997. The developed method was validated with excellent specificity, sensitivity, accuracy, precision and stability. Using this developed method, the pharmacokinetics of moxifloxacin in healthy Chinese volunteers was studied.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21093388     DOI: 10.1016/j.jchromb.2010.10.024

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

Review 1.  Interethnic differences in pharmacokinetics of antibacterials.

Authors:  Danny Tsai; Janattul-Ain Jamal; Joshua S Davis; Jeffrey Lipman; Jason A Roberts
Journal:  Clin Pharmacokinet       Date:  2015-03       Impact factor: 6.447

2.  Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors.

Authors:  Mohammed M Hefnawy; Atef M Homoda; Mohammed A Abounassif; Amer M Alanazi; Abdulrahaman Al-Majed; Gamal A Mostafa
Journal:  Chem Cent J       Date:  2014-09-17       Impact factor: 4.215

Review 3.  Analytical Methods for Determining Third and Fourth Generation Fluoroquinolones: A Review.

Authors:  Andrzej Czyrski
Journal:  Chromatographia       Date:  2016-12-23       Impact factor: 2.044

4.  Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode.

Authors:  M Shehata; Amany M Fekry; Alain Walcarius
Journal:  Sensors (Basel)       Date:  2020-05-14       Impact factor: 3.576

5.  Improved HPLC method for the determination of moxifloxacin in application to a pharmacokinetics study in patients with infectious diseases.

Authors:  Nan Wang; Liqin Zhu; Xuequn Zhao; Wenjie Yang; He Sun
Journal:  ISRN Pharmacol       Date:  2013-05-26

6.  Fiberoptic-Coupled Spectrofluorometer with Array Detection as a Process Analytical Chemistry Tool for Continuous Flow Monitoring of Fluoroquinolone Antibiotics.

Authors:  Nader Shokoufi; Maryam Vosough; Mona Rahimzadegan-Asl; Atefeh Abbasi-Ahd; Mahsa Khatibeghdami
Journal:  Int J Anal Chem       Date:  2020-02-07       Impact factor: 1.885

  6 in total