Radiation Oncology Safety Information System (ROSIS)--profiles of participants and the first 1074 incident reports.

Joanne Cunningham1, Mary Coffey, Tommy Knöös, Ola Holmberg.   

Abstract

BACKGROUND AND
PURPOSE: The Radiation Oncology Safety Information System (ROSIS) was established in 2001. The aim of ROSIS is to collate and share information on incidents and near-incidents in radiotherapy, and to learn from these incidents in the context of departmental infrastructure and procedures.
MATERIALS AND METHODS: A voluntary web-based cross-organisational and international reporting and learning system was developed (cf. the www.rosis.info website). Data is collected via online Department Description and Incident Report Forms. A total of 101 departments, and 1074 incident reports are reviewed.
RESULTS: The ROSIS departments represent about 150,000 patients, 343 megavoltage (MV) units, and 114 brachytherapy units. On average, there are 437 patients per MV unit, 281 per radiation oncologist, 387 per physicist and 353 per radiation therapy technologist (RT/RTT). Only 14 departments have a completely networked system of electronic data transfer, while 10 departments have no electronic data transfer. On average seven quality assurance (QA) or quality control (QC) methods are used at each department. A total of 1074 ROSIS reports are analysed; 97.7% relate to external beam radiation treatment and 50% resulted in incorrect irradiation. Many incidents arise during pre-treatment but are not detected until later in the treatment process. Where an incident is not detected prior to treatment, an average of 22% of the prescribed treatment fractions were delivered incorrectly. The most commonly reported detection methods were "found at time of patient treatment" and during "chart-check".
CONCLUSION: While the majority of the incidents that reported to this international cross-organisational reporting system are of minor dosimetric consequence, they affect on average more than 20% of the patient's treatment fractions. Nonetheless, defence-in-depth is apparent in departments registered with ROSIS. This indicates a need for further evaluation of the effectiveness of quality controls.
Copyright © 2010. Published by Elsevier Ireland Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 21087801     DOI: 10.1016/j.radonc.2010.10.023

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  19 in total

Review 1.  In vivo dosimetry: trends and prospects for brachytherapy.

Authors:  G Kertzscher; A Rosenfeld; S Beddar; K Tanderup; J E Cygler
Journal:  Br J Radiol       Date:  2014-07-08       Impact factor: 3.039

2.  Standardizing naming conventions in radiation oncology.

Authors:  Lakshmi Santanam; Coen Hurkmans; Sasa Mutic; Corine van Vliet-Vroegindeweij; Scott Brame; William Straube; James Galvin; Prabhakar Tripuraneni; Jeff Michalski; Walter Bosch
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-01-13       Impact factor: 7.038

3.  Application of an incident taxonomy for radiation therapy: Analysis of five years of data from three integrated cancer centres.

Authors:  Stuart Greenham; Stephen Manley; Kirsty Turnbull; Matthew Hoffmann; Amara Fonseca; Justin Westhuyzen; Andrew Last; Noel J Aherne; Thomas P Shakespeare
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-10

4.  Critical success factors for implementation of an incident learning system in radiation oncology department.

Authors:  Lucas Augusto Radicchi; José Carlos de Toledo; Dário Henrique Alliprandini
Journal:  Rep Pract Oncol Radiother       Date:  2020-10-03

5.  Quality assurance in radiotherapy on a national level; experience from Norway: the KVIST initiative.

Authors:  Taran Paulsen Hellebust; Ingrid Espe Heikkilä; Gunilla Frykholm; Sverre Levernes; Dag Clement Johannessen; Hans Bjerke; Hilde Olerud
Journal:  J Radiother Pract       Date:  2013-04-22

6.  Incident Learning and Failure-Mode-and-Effects-Analysis Guided Safety Initiatives in Radiation Medicine.

Authors:  Ajay Kapur; Gina Goode; Catherine Riehl; Petrina Zuvic; Sherin Joseph; Nilda Adair; Michael Interrante; Beatrice Bloom; Lucille Lee; Rajiv Sharma; Anurag Sharma; Jeffrey Antone; Adam Riegel; Lili Vijeh; Honglai Zhang; Yijian Cao; Carol Morgenstern; Elaine Montchal; Brett Cox; Louis Potters
Journal:  Front Oncol       Date:  2013-12-16       Impact factor: 6.244

7.  Quality and safety considerations in stereotactic radiosurgery and stereotactic body radiation therapy: Executive summary.

Authors:  Timothy D Solberg; James M Balter; Stanley H Benedict; Benedick A Fraass; Brian Kavanagh; Curtis Miyamoto; Todd Pawlicki; Louis Potters; Yoshiya Yamada
Journal:  Pract Radiat Oncol       Date:  2011-09-15

8.  Implementation of incident learning in the safety and quality management of radiotherapy: the primary experience in a new established program with advanced technology.

Authors:  Ruijie Yang; Junjie Wang; Xile Zhang; Haitao Sun; Yang Gao; Lu Liu; Lei Lin
Journal:  Biomed Res Int       Date:  2014-07-22       Impact factor: 3.411

9.  Recommendations for safer radiotherapy: what's the message?

Authors:  Peter Dunscombe
Journal:  Front Oncol       Date:  2012-09-28       Impact factor: 6.244

10.  The role of medical physicists in clinical trials: More than quality assurance.

Authors:  Tomas Kron
Journal:  J Med Phys       Date:  2013-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.