Mechanical circulatory support with the ABIOMED BVS 5000: the Toronto General Hospital experience.

Vidyadhar Lad1, Abdelsalam Elhenawy, Steve Harwood, Jane Maciver, Mitesh Vallabh Badiwala, Mark Vallelonga, Terrence M Yau, Robert J Cusimano, Diego H Delgado, Heather J Ross, Vivek Rao.   

Abstract

BACKGROUND: Acute hemodynamic collapse resulting in cardiogenic shock and impending end-organ failure is usually associated with certain death. The introduction of short-term mechanical circulatory support (MCS) devices offers potential therapy to these critically ill patients. The BVS 5000 device (ABIOMED Inc, USA) is widely used in the United States, but rarely in Canada, where device reimbursement remains a barrier.
OBJECTIVE: To present the Toronto General Hospital's (Toronto, Ontario) initial five-year experience with this device to highlight the indications for use, common complications and overall success rates. METHODS AND
RESULTS: The institutional MCS database from 2001 to 2006 was reviewed, and 18 patients who received 30 devices in a variety of configurations were identified. The most common support configuration consisted of biventricular support (n=12), followed by isolated left ventricular support (n=4) and isolated right ventricular support in two recipients of an implantable long-term left ventricular assist device. Overall survival to device explant or transplant was 55% (n=10), of which five (50%) were successfully discharged from the hospital. The overall survival from device implant to hospital discharge was 28% (five of 18). The most common cause of death was multisystem organ failure.
CONCLUSIONS: MCS with the ABIOMED BVS 5000 can successfully resuscitate critically ill patients; however, earlier institution of this device would avoid irreversible end-organ injury, and lead to higher rates of device explant and hospital discharge. Short-term MCS devices should be available in all cardiac surgical centres in Canada to permit stabilization and evaluation of the acutely ill cardiac patient and subsequent management in a heart transplant facility.

Entities:  

Mesh:

Year:  2010        PMID: 21076718      PMCID: PMC2989351          DOI: 10.1016/s0828-282x(10)70449-9

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  21 in total

1.  Mechanical circulatory support of heart transplant patients.

Authors:  O Arafa; A E Fiane; J L Svennevig; O R Geiran
Journal:  Transplant Proc       Date:  2001 Feb-Mar       Impact factor: 1.066

2.  Fulminant myocarditis.

Authors:  J S Karliner
Journal:  N Engl J Med       Date:  2000-03-09       Impact factor: 91.245

3.  Left ventricular assist device bridge-to-transplant network improves survival after failed cardiotomy.

Authors:  D N Helman; D L Morales; N M Edwards; D M Mancini; J M Chen; E A Rose; M C Oz
Journal:  Ann Thorac Surg       Date:  1999-10       Impact factor: 4.330

4.  A new off-pump technique for thoratec right ventricular assist device insertion.

Authors:  V Rao; M C Oz; N M Edwards; Y Naka
Journal:  Ann Thorac Surg       Date:  2001-05       Impact factor: 4.330

5.  Five-year clinical experience with Abiomed BVS 5000 as a ventricular assist device for cardiac failure.

Authors:  R J Dekkers; D J FitzGerald; G S Couper
Journal:  Perfusion       Date:  2001-01       Impact factor: 1.972

6.  Management of acute cardiac failure with mechanical assist: experience with the ABIOMED BVS 5000.

Authors:  L E Samuels; E C Holmes; M P Thomas; J C Entwistle; R J Morris; J Narula; A S Wechsler
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

7.  Differential indication for mechanical circulatory support following heart transplantation.

Authors:  P A Minev; A El-Banayosy; K Minami; H Körtke; L Kizner; R Körfer
Journal:  Intensive Care Med       Date:  2001-08       Impact factor: 17.440

8.  Temporary pulsatile ventricular assist devices and biventricular assist devices.

Authors:  R Körfer; A El-Banayosy; L Arusoglu; K Minami; T Breymann; D Seifert; L Kizner
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

Review 9.  BVS5000 support after cardiac transplantation.

Authors:  Jason A Petrofski; Vijay S Patel; Stuart D Russell; Carmelo A Milano
Journal:  J Thorac Cardiovasc Surg       Date:  2003-08       Impact factor: 5.209

10.  Role of the Abiomed BVS 5000 device for short-term support and bridge to transplantation.

Authors:  Jeffrey A Morgan; Allan S Stewart; Brian J Lee; Mehmet C Oz; Yoshifumi Naka
Journal:  ASAIO J       Date:  2004 Jul-Aug       Impact factor: 2.872

View more
  1 in total

1.  Finite Element Driven Design Domain Identification of a Beating Left Ventricular Simulator.

Authors:  Utku Gulbulak; Atila Ertas
Journal:  Bioengineering (Basel)       Date:  2019-09-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.