Literature DB >> 21070259

Learning curve for zero-fluoroscopy catheter ablation of AVNRT: early versus late experience.

Katja Gist1, Cody Tigges, Grace Smith, John Clark.   

Abstract

INTRODUCTION/
BACKGROUND: Three-dimensional catheter navigation systems are being utilized more frequently to minimize or eliminate fluoroscopy during catheter ablation. We reviewed our learning curve for a zero-fluoroscopy approach over a 32-month period.
METHODS: Data were obtained retrospectively from 62 consecutive patients who underwent cryoablation of AVNRT without the use of fluoroscopy from December 2005 to August 2008. The early era was defined as the first 12 months of procedures (December 2005-December 2006, n = 27) and the recent era thereafter (January 2007-August 2008, n = 35).
RESULTS: In the early era, acute success was achieved in 100% of patients, compared to 97% in the recent era. There were no significant complications in either group. Transient AV block was seen frequently; however, this always resolved quickly. Average procedure time for the early era was 202 minutes (100-419 minutes) compared to 160 minutes (78-332 minutes) in the recent era (P = 0.01). Recurrence rates were 15% and 8% for the early and recent era, respectively.
CONCLUSION: Procedure time significantly shortens as a function of experience. After an adequate learning curve, the procedure can be performed in a very acceptable amount of time. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21070259     DOI: 10.1111/j.1540-8159.2010.02952.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  10 in total

1.  Efficacy and safety of zero-fluoroscopy ablation for supraventricular tachycardias. Use of optional contact force measurement for zero-fluoroscopy ablation in a clinical routine setting.

Authors:  P Seizer; V Bucher; C Frische; D Heinzmann; M Gramlich; I Müller; A Henning; M Hofbeck; G Kerst; M Gawaz; J Schreieck
Journal:  Herz       Date:  2015-10-13       Impact factor: 1.443

2.  Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learned.

Authors:  Roberto De Ponti
Journal:  World J Cardiol       Date:  2015-08-26

Review 3.  The Growing Culture Of A Minimally Fluoroscopic Approach In Electrophysiology Lab.

Authors:  Michela Casella; Eleonora Russo; Francesca Pizzamiglio; Sergio Conti; Ghaliah Al-Mohani; Daniele Colombo; Victor Casula; Yuri D Alessandra; Viviana Biagioli; Corrado Carbucicchio; Stefania Riva; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Vittoria Marino; Giovanni Forleo; Pasquale Santangeli; Luigi Di Biase; Antonio Dello Russo; Andrea Natale; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2014-08-31

Review 4.  Catheter Ablation of Atrial Fibrillation Without Radiation Exposure Using A 3D Mapping System.

Authors:  Marco Scaglione; Elisa Ebrille; Francesca Di Clemente; Fiorenzo Gaita; Jason S Bradfield
Journal:  J Atr Fibrillation       Date:  2015-02-28

5.  Outcomes During Intended Fluoroscopy-free Ablation in Adults and Children.

Authors:  Ryan T Kipp; Jason R Boynton; Michael E Field; Jesse F Wang; Anton Bares; Miguel A Leal; Nicholas H VON Bergen; Lee L Eckhardt
Journal:  J Innov Card Rhythm Manag       Date:  2018-09

6.  Electroanatomic mapping-guided pediatric catheter ablation with limited/zero fluoroscopy.

Authors:  Serhat Koca; Feyza Ayşenur Paç; Deniz Eriş; Merve Maze Zabun; Özcan Özeke; Fırat Özcan
Journal:  Anatol J Cardiol       Date:  2018-09       Impact factor: 1.596

7.  Extensive Use of 3D Nonfluoroscopic Mapping Systems for Reducing Radiation Exposure during Catheter Ablation Procedures: An Analysis of 10 Years of Activity.

Authors:  Massimiliano Marini; Marta Martin; Daniele Ravanelli; Maurizio Del Greco; Silvia Quintarelli; Fabrizio Guarracini; Alessio Coser; Aldo Valentini; Roberto Bonmassari
Journal:  Biomed Res Int       Date:  2019-03-10       Impact factor: 3.411

8.  Aegrescit medendo: orthopedic disability in electrophysiology - call for fluoroscopy elimination-review and commentary.

Authors:  Donald S Rubenstein; Benjamin B Holmes; Joseph A Manfredi; Matthew S McKillop; Peter C Netzler; Chad C Ward
Journal:  J Interv Card Electrophysiol       Date:  2022-03-08       Impact factor: 1.759

9.  Post-ablation prolongation of atrioventricular nodal refractory period is correlated with long-term success of cryoablation for atrioventricular nodal reentrant tachycardia in the case of the persistence of a residual jump.

Authors:  Joelci Tonet; Antonio De Sisti; Natalia Pardo Restrepo; Denis Raguin; Walid Amara; Manlio F Márquez; Philip Aouate; Xavier Waintraub; Faouzi Touil; Francoise Hidden-Lucet
Journal:  J Interv Card Electrophysiol       Date:  2012-05-05       Impact factor: 1.900

Review 10.  Zero-fluoroscopy catheter ablation of severe drug-resistant arrhythmia guided by Ensite NavX system during pregnancy: Two case reports and literature review.

Authors:  Guangzhi Chen; Ge Sun; Renfan Xu; Xiaomei Chen; Li Yang; Yang Bai; Shanshan Yang; Ping Guo; Yan Zhang; Chunxia Zhao; Dao Wen Wang; Yan Wang
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.