The outcome of carotid artery stenting (CAS) depends on a proper selection of patients and devices, requiring dedicated tools able to relate the device features with the target vessel. In the present study, we use finite element analysis to evaluate the performance of three self-expanding stent designs (laser-cut open-cell, laser-cut closed-cell, braided closed-cell) in a carotid artery (CA). We define six stent models considering the three designs in different sizes and configurations (i.e. straight and tapered), evaluating the stress induced in the vessel wall, the lumen gain and the vessel straightening in a patient-specific CA model based on computed angiography tomography (CTA) images. For the considered vascular anatomy and stents, the results suggest that: (i) the laser-cut closed-cell design provides a higher lumen gain; (ii) the impact of the stent configuration and of the stent oversizing is negligible with respect to the lumen gain and relevant with respect to the stress induced in the vessel wall; (iii) stent design, configuration and size have a limited impact on the vessel straightening. The presented numerical model represents a first step towards a quantitative assessment of the relation between a given carotid stent design and a given patient-specific CA anatomy.
Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21067964     DOI: 10.1016/j.medengphy.2010.10.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  23 in total

1.  Carotid vasculature modeling from patient CT angiography studies for interventional procedures simulation.

Authors:  M Freiman; L Joskowicz; N Broide; M Natanzon; E Nammer; O Shilon; L Weizman; J Sosna
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-02-29       Impact factor: 2.924

Review 2.  Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease.

Authors:  Guido H W van Bogerijen; Jip L Tolenaar; Michele Conti; Ferdinando Auricchio; Francesco Secchi; Francesco Sardanelli; Frans L Moll; Joost A van Herwaarden; Vincenzo Rampoldi; Santi Trimarchi
Journal:  Aorta (Stamford)       Date:  2013-08-01

3.  Structural analysis for Wingspan stent in a perforator model.

Authors:  Motoaki Fujimoto; Yasuhiro Shobayashi; Koichiro Takemoto; Satoshi Tateshima; Fernando Viñuela
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

4.  Temporal correlation between wall shear stress and in-stent stenosis after Wingspan stent in swine model.

Authors:  M Fujimoto; H Takao; T Suzuki; Y Shobayashi; F Mayor; S Tateshima; M Yamamoto; Y Murayama; F Viñuela
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-14       Impact factor: 3.825

5.  The impact of balloon-expandable transcatheter aortic valve replacement on concomitant mitral regurgitation: a comprehensive computational analysis.

Authors:  Andrés Caballero; Wenbin Mao; Raymond McKay; Wei Sun
Journal:  J R Soc Interface       Date:  2019-08-14       Impact factor: 4.118

6.  The role of stress concentration in calcified bicuspid aortic valve.

Authors:  Tongran Qin; Andrés Caballero; Wenbin Mao; Brian Barrett; Norihiko Kamioka; Stamatios Lerakis; Wei Sun
Journal:  J R Soc Interface       Date:  2020-06-10       Impact factor: 4.118

7.  An inverse method for mechanical characterization of heterogeneous diseased arteries using intravascular imaging.

Authors:  Bharath Narayanan; Max L Olender; David Marlevi; Elazer R Edelman; Farhad R Nezami
Journal:  Sci Rep       Date:  2021-11-18       Impact factor: 4.379

8.  Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty.

Authors:  Thuy Pham; Milton Deherrera; Wei Sun
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-02-13       Impact factor: 1.763

9.  High-quality conforming hexahedral meshes of patient-specific abdominal aortic aneurysms including their intraluminal thrombi.

Authors:  J Tarjuelo-Gutierrez; B Rodriguez-Vila; D M Pierce; T E Fastl; P Verbrugghe; I Fourneau; G Maleux; P Herijgers; G A Holzapfel; E J Gomez
Journal:  Med Biol Eng Comput       Date:  2013-12-05       Impact factor: 2.602

10.  The Impact of Self-Expandable Transcatheter Aortic Valve Replacement on Concomitant Functional Mitral Regurgitation: A Comprehensive Engineering Analysis.

Authors:  Andrés Caballero; Wenbin Mao; Raymond McKay; Wei Sun
Journal:  Struct Heart       Date:  2020-04-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.