Literature DB >> 24306943

High-quality conforming hexahedral meshes of patient-specific abdominal aortic aneurysms including their intraluminal thrombi.

J Tarjuelo-Gutierrez1, B Rodriguez-Vila, D M Pierce, T E Fastl, P Verbrugghe, I Fourneau, G Maleux, P Herijgers, G A Holzapfel, E J Gomez.   

Abstract

In order to perform finite element (FE) analyses of patient-specific abdominal aortic aneurysms, geometries derived from medical images must be meshed with suitable elements. We propose a semi-automatic method for generating conforming hexahedral meshes directly from contours segmented from medical images. Magnetic resonance images are generated using a protocol developed to give the abdominal aorta high contrast against the surrounding soft tissue. These data allow us to distinguish between the different structures of interest. We build novel quadrilateral meshes for each surface of the sectioned geometry and generate conforming hexahedral meshes by combining the quadrilateral meshes. The three-layered morphology of both the arterial wall and thrombus is incorporated using parameters determined from experiments. We demonstrate the quality of our patient-specific meshes using the element Scaled Jacobian. The method efficiently generates high-quality elements suitable for FE analysis, even in the bifurcation region of the aorta into the iliac arteries. For example, hexahedral meshes of up to 125,000 elements are generated in less than 130 s, with 94.8 % of elements well suited for FE analysis. We provide novel input for simulations by independently meshing both the arterial wall and intraluminal thrombus of the aneurysm, and their respective layered morphologies.

Entities:  

Mesh:

Year:  2013        PMID: 24306943     DOI: 10.1007/s11517-013-1127-5

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Pathogenesis of abdominal aortic aneurysms: a multidisciplinary research program supported by the National Heart, Lung, and Blood Institute.

Authors:  M Wassef; B T Baxter; R L Chisholm; R L Dalman; M F Fillinger; J Heinecke; J D Humphrey; H Kuivaniemi; W C Parks; W H Pearce; C D Platsoucas; G K Sukhova; R W Thompson; M D Tilson; C K Zarins
Journal:  J Vasc Surg       Date:  2001-10       Impact factor: 4.268

2.  Determination of the layer-specific distributed collagen fibre orientations in human thoracic and abdominal aortas and common iliac arteries.

Authors:  Andreas J Schriefl; Georg Zeindlinger; David M Pierce; Peter Regitnig; Gerhard A Holzapfel
Journal:  J R Soc Interface       Date:  2011-12-14       Impact factor: 4.118

3.  Effects of mesh style and grid convergence on particle deposition in bifurcating airway models with comparisons to experimental data.

Authors:  P Worth Longest; Samir Vinchurkar
Journal:  Med Eng Phys       Date:  2006-06-30       Impact factor: 2.242

4.  Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur.

Authors:  A Ramos; J A Simões
Journal:  Med Eng Phys       Date:  2006-02-07       Impact factor: 2.242

5.  Effects of age on the elastic properties of the intraluminal thrombus and the thrombus-covered wall in abdominal aortic aneurysms: biaxial extension behaviour and material modelling.

Authors:  J Tong; T Cohnert; P Regitnig; G A Holzapfel
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-03-25       Impact factor: 7.069

6.  Carotid artery stenting simulation: from patient-specific images to finite element analysis.

Authors:  F Auricchio; M Conti; M De Beule; G De Santis; B Verhegghe
Journal:  Med Eng Phys       Date:  2010-11-09       Impact factor: 2.242

7.  Patient-specific computational haemodynamics: generation of structured and conformal hexahedral meshes from triangulated surfaces of vascular bifurcations.

Authors:  G De Santis; M De Beule; P Segers; P Verdonck; B Verhegghe
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-05-24       Impact factor: 1.763

8.  Patient-specific computational fluid dynamics: structured mesh generation from coronary angiography.

Authors:  Gianluca De Santis; Peter Mortier; Matthieu De Beule; Patrick Segers; Pascal Verdonck; Benedict Verhegghe
Journal:  Med Biol Eng Comput       Date:  2010-02-17       Impact factor: 2.602

9.  Geometric reconstruction for computational mesh generation of arterial bifurcations from CT angiography.

Authors:  Luca Antiga; Bogdan Ene-Iordache; Lionello Caverni; Gian Paolo Cornalba; Andrea Remuzzi
Journal:  Comput Med Imaging Graph       Date:  2002 Jul-Aug       Impact factor: 4.790

10.  A comparative study of aortic wall stress using finite element analysis for ruptured and non-ruptured abdominal aortic aneurysms.

Authors:  A K Venkatasubramaniam; M J Fagan; T Mehta; K J Mylankal; B Ray; G Kuhan; I C Chetter; P T McCollum
Journal:  Eur J Vasc Endovasc Surg       Date:  2004-08       Impact factor: 7.069

View more
  1 in total

1.  Fast in silico assessment of physical stress for peripheral nerves.

Authors:  Elisabetta Giannessi; Maria Rita Stornelli; Pier Nicola Sergi
Journal:  Med Biol Eng Comput       Date:  2018-02-12       Impact factor: 2.602

  1 in total