The use of reservoir devices for the simultaneous delivery of two metered-dose aerosols.

A R Clark1, G Rachelefsky, P L Mason, M J Goldenhersh, A Hollingworth.   

Abstract

Many patients benefit from using metered-dose inhalers (MDIs) with spacer or reservoir devices. Concomitant therapy with separate MDI doses of cromolyn sodium and a beta-agonist is common practice. If two puffs from each drug could be placed into a chamber, the patient could administer both medications at once, enhancing compliance. A multistage liquid impinger (a four-stage inertial impaction device incorporating an inlet bend and an absolute filter, which separates an aerosol cloud into six fractions) was used to investigate such a possibility. Cromolyn sodium and albuterol MDIs were used with an Aerochamber (Monaghan Medical Corp., Plattsburgh, N.Y.) and an Inspirease (Schering Corp., Kenilworth, N.J.). Results are reported by analyzing milligrams of cromolyn sodium per actuation retrieved. With the Aerochamber, two puffs of cromolyn sodium followed by two puffs of albuterol resulted in the total "dose to patient" being reduced by 75% (0.19 versus 0.05 mg) and the effective dose of fine particles (less than 6.5 microns) being reduced by 80% (0.13 versus 0.03 mg) compared to two puffs of cromolyn sodium alone. With the Inspirease, total dose was decreased by 80% (0.32 versus 0.06 mg), whereas the effective dose of fine particles was reduced by 60% (0.19 versus 0.05 mg) compared to one puff of cromolyn sodium alone. The use of cromolyn sodium and albuterol MDIs in a multipuff combination with the Aerochamber or the Inspirease is not recommended because this leads to a loss of the dose delivered compared to a single administration.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2105348     DOI: 10.1016/0091-6749(90)90224-r

Source DB:  PubMed          Journal:  J Allergy Clin Immunol        ISSN: 0091-6749            Impact factor:   10.793


  4 in total

1.  Prediction and assessment of flammability hazards associated with metered-dose inhalers containing flammable propellants.

Authors:  R N Dalby
Journal:  Pharm Res       Date:  1992-05       Impact factor: 4.200

2.  The effect of delay, multiple actuations and spacer static charge on the in vitro delivery of budesonide from the Nebuhaler.

Authors:  P W Barry; C O'Callaghan
Journal:  Br J Clin Pharmacol       Date:  1995-07       Impact factor: 4.335

3.  Optimum use of a spacer device.

Authors:  P W Barry; C F Robertson; C O'Callaghan
Journal:  Arch Dis Child       Date:  1993-12       Impact factor: 3.791

4.  Factors affecting total and "respirable" dose delivered by a salbutamol metered dose inhaler.

Authors:  M L Everard; S G Devadason; Q A Summers; P N Le Souëf
Journal:  Thorax       Date:  1995-07       Impact factor: 9.139