Literature DB >> 18809281

Dynamic aortic changes in patients with thoracic aortic aneurysms evaluated with electrocardiography-triggered computed tomographic angiography before and after thoracic endovascular aneurysm repair: preliminary results.

Joffrey van Prehn1, Lambertus W Bartels, Gaspar Mestres, Koen L Vincken, Mathias Prokop, Hence J M Verhagen, Frans L Moll, Joost A van Herwaarden.   

Abstract

The purpose of this study was to utilize dynamic computed tomographic angiography (CTA) on pre- and postoperative thoracic endovascular aneurysm repair (TEVAR) patients to characterize cardiac pulsatility-induced aortic motion on essential TEVAR proximal sealing zones and to study the influence of endograft placement. Six pre- and six postoperative dynamic CTA studies were obtained in six patients with thoracic aortic aneurysms (TAAs) undergoing TEVAR. Data were acquired using a retrospective electrocardiography-triggered dynamic CTA scan, with eight reconstructed phases over the cardiac cycle. Scans were acquired during a single breath hold. Multiplanar reconstructions were made perpendicular to the aorta at five surgically relevant anatomical thoracic landmarks: 1 cm proximal to the innominate trunk, 1 cm proximal and 1 cm distal to the left subclavian artery, and 1 cm proximal and 3 cm distal to the proximal end of the stent. After segmentation of the aortic lumen in the images, diameter change and area change over the cardiac cycle were measured. Diameter change was measured through the center of mass of the aortic lumen, and the average change over 180 axis is presented. We found significant distention of the thoracic aortic arch and descending thoracic aorta during the cardiac cycle before and after TEVAR. Distention ranged 3-12% in diameter and 2-20% in area. This distention was preserved after TEVAR. Patients with TAA experience aortic diameter and area changes during the cardiac cycle. The magnitude, and hence the clinical importance, of this aortic distention varies among patients. After stent-graft placement, aortic distention throughout the cardiac cycle is preserved. This may have major implications for correct sizing of the endograft as well as for stent-graft design and durability as the forces on the stents may be much larger after implantation than initially anticipated by stent manufacturers.

Entities:  

Mesh:

Year:  2008        PMID: 18809281     DOI: 10.1016/j.avsg.2008.08.007

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  7 in total

1.  Low dose dual-source CT angiography of the thoracic aorta.

Authors:  Cormac Farrelly; Amir Davarpanah; Aoife N Keeling; John Sheehan; Ann Ragin; Vahid Yaghmai; James C Carr
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-03       Impact factor: 2.357

Review 2.  Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease.

Authors:  Guido H W van Bogerijen; Jip L Tolenaar; Michele Conti; Ferdinando Auricchio; Francesco Secchi; Francesco Sardanelli; Frans L Moll; Joost A van Herwaarden; Vincenzo Rampoldi; Santi Trimarchi
Journal:  Aorta (Stamford)       Date:  2013-08-01

3.  Importance of dynamic aortic evaluation in planning TEVAR.

Authors:  Guido H W van Bogerijen; Joost A van Herwaarden; Michele Conti; Ferdinando Auricchio; Vincenzo Rampoldi; Santi Trimarchi; Frans L Moll
Journal:  Ann Cardiothorac Surg       Date:  2014-05

4.  Influence of Cardiovascular Risk Factors on Aortic Wall Motion After Repair of Type A Aortic Dissection: An Electrocardiography-Gated Computed Tomography Study.

Authors:  Mariagrazia Croccia; Maurizio Levantino; Paolo Marraccini; Federico Franchi; Uberto Bortolotti
Journal:  Aorta (Stamford)       Date:  2013-10-01

5.  A simple patient-tailored aortic arch tangential angle measuring method to achieve better clinical results for thoracic endovascular repair of type B aortic dissection.

Authors:  Lixin Wang; Kai Hou; Xin Xu; Bin Chen; Junhao Jiang; Zhenyu Shi; Xiao Tang; Daqiao Guo; Weiguo Fu
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

6.  Multiaxial pulsatile dynamics of the thoracic aorta and impact of thoracic endovascular repair.

Authors:  Ga-Young Suh; Johan Bondesson; Yufei D Zhu; Jason T Lee; Michael D Dake; Christopher P Cheng
Journal:  Eur J Radiol Open       Date:  2021-03-11

7.  Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model.

Authors:  Hector W L de Beaufort; Margherita Coda; Michele Conti; Theodorus M J van Bakel; Foeke J H Nauta; Ettore Lanzarone; Frans L Moll; Joost A van Herwaarden; Ferdinando Auricchio; Santi Trimarchi
Journal:  PLoS One       Date:  2017-10-05       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.