Literature DB >> 21042927

Indoor air quality in elementary schools of Lisbon in spring.

P N Pegas1, C A Alves, M G Evtyugina, T Nunes, M Cerqueira, M Franchi, C A Pio, S M Almeida, M C Freitas.   

Abstract

Analysis of indoor air quality (IAQ) in schools usually reveals higher levels of pollutants than in outdoor environments. The aims of this study are to measure indoor and outdoor concentrations of NO(2), speciated volatile organic compounds (VOCs) and carbonyls at 14 elementary schools in Lisbon, Portugal. The investigation was carried out in May-June 2009. Three of the schools were selected to also measure comfort parameters, such as temperature and relative humidity, carbon dioxide (CO(2)), carbon monoxide (CO), total VOCs, and bacterial and fungal colony-forming units per cubic metre. Indoor concentrations of CO(2) in the three main schools indicated inadequate classroom air exchange rates. The indoor/outdoor (I/O) NO(2) ratio ranged between 0.36 and 0.95. At the three main schools, the total bacterial and fungal colony-forming units (CFU) in both indoor and outdoor air were above the advised maximum value of 500 CFU/m(3) defined by Portuguese legislation. The aromatic compounds benzene, toluene, ethylbenzene and xylenes, followed by ethers, alcohols and terpenes, were usually the most abundant classes of VOCs. In general, the indoor total VOC concentrations were markedly higher than those observed outdoors. At all locations, indoor aldehyde levels were higher than those observed outdoors, particularly for formaldehyde. The inadequate ventilation observed likely favours accumulation of pollutants with additional indoor sources.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21042927     DOI: 10.1007/s10653-010-9345-3

Source DB:  PubMed          Journal:  Environ Geochem Health        ISSN: 0269-4042            Impact factor:   4.609


  41 in total

1.  The efficiency of various liquid impinger samplers in bacterial aerosols.

Authors:  K R MAY; G J HARPER
Journal:  Br J Ind Med       Date:  1957-10

2.  Evidence of inadequate ventilation in portable classrooms: results of a pilot study in Los Angeles County.

Authors:  D G Shendell; A M Winer; R Weker; S D Colome
Journal:  Indoor Air       Date:  2004-06       Impact factor: 5.770

3.  Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes.

Authors:  Wan-Kuen Jo; Young-Jun Seo
Journal:  Chemosphere       Date:  2005-06-27       Impact factor: 7.086

4.  Spatial analysis and land use regression of VOCs and NO(2) from school-based urban air monitoring in Detroit/Dearborn, USA.

Authors:  Shaibal Mukerjee; Luther A Smith; Mary M Johnson; Lucas M Neas; Casson A Stallings
Journal:  Sci Total Environ       Date:  2009-05-20       Impact factor: 7.963

5.  Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong.

Authors:  S C Lee; W M Li; L Y Chan
Journal:  Sci Total Environ       Date:  2001-11-12       Impact factor: 7.963

6.  Indoor air quality at nine shopping malls in Hong Kong.

Authors:  W M Li; S C Lee; L Y Chan
Journal:  Sci Total Environ       Date:  2001-06-12       Impact factor: 7.963

7.  Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools.

Authors:  G L Chew; J C Correa; M S Perzanowski
Journal:  Indoor Air       Date:  2005-08       Impact factor: 5.770

Review 8.  The German view: effects of nitrogen dioxide on human health--derivation of health-related short-term and long-term values.

Authors:  Martin Kraft; Thomas Eikmann; Andreas Kappos; Nino Künzli; Regula Rapp; Klaus Schneider; Heike Seitz; Jens-Uwe Voss; H Erich Wichmann
Journal:  Int J Hyg Environ Health       Date:  2005       Impact factor: 5.840

9.  Indoor air microbes and respiratory symptoms of children in moisture damaged and reference schools.

Authors:  T Meklin; T Husman; A Vepsäläinen; M Vahteristo; J Koivisto; J Halla-Aho; A Hyvärinen; D Moschandreas; A Nevalainen
Journal:  Indoor Air       Date:  2002-09       Impact factor: 5.770

10.  Asthmatic symptoms among pupils in relation to winter indoor and outdoor air pollution in schools in Taiyuan, China.

Authors:  Zhuohui Zhao; Zheng Zhang; Zhuanhua Wang; Martin Ferm; Yanling Liang; Dan Norbäck
Journal:  Environ Health Perspect       Date:  2008-01       Impact factor: 9.031

View more
  15 in total

1.  Infection risk in gyms during physical exercise.

Authors:  Alexandro Andrade; Fábio Hech Dominski; Marcelo Luiz Pereira; Carla Maria de Liz; Giorgio Buonanno
Journal:  Environ Sci Pollut Res Int       Date:  2018-05-07       Impact factor: 4.223

2.  Radon in indoor concentrations and indoor concentrations of metal dust particles in museums and other public buildings.

Authors:  G L Carneiro; D Braz; E F de Jesus; S M Santos; K Cardoso; A A Hecht; Moore K Dias da Cunha
Journal:  Environ Geochem Health       Date:  2012-11-04       Impact factor: 4.609

3.  Indoor air quality (IAQ) assessment in a multistorey shopping mall by high-spatial-resolution monitoring of volatile organic compounds (VOC).

Authors:  M Amodio; P R Dambruoso; Gianluigi de Gennaro; L de Gennaro; A Demarinis Loiotile; A Marzocca; F Stasi; L Trizio; M Tutino
Journal:  Environ Sci Pollut Res Int       Date:  2014-01-22       Impact factor: 4.223

4.  A cross-sectional survey based on blood VOCs, hematological parameters and urine indicators in a population in Jilin, Northeast China.

Authors:  Xiaocui Li; Yuanyuan Guo; Xiuling Song; Yinghua He; Huiwen Zhang; Hao Bao; Xinxin Li; Yushen Liu; Yue Zhai; Juan Wang; Kun Xu; Juan Li
Journal:  Environ Geochem Health       Date:  2019-01-16       Impact factor: 4.609

5.  Indoor air quality at life and work environments in Rome, Italy.

Authors:  P Romagnoli; C Balducci; M Perilli; F Vichi; A Imperiali; A Cecinato
Journal:  Environ Sci Pollut Res Int       Date:  2015-10-21       Impact factor: 4.223

6.  Indoor air quality and atopic sensitization in primary schools: A follow-up study.

Authors:  João Cavaleiro Rufo; Joana Madureira; Inês Paciência; Lívia Aguiar; João Paulo Teixeira; André Moreira; Eduardo de Oliveira Fernandes
Journal:  Porto Biomed J       Date:  2016-08-10

7.  Indoor air quality and health in schools.

Authors:  Ana Maria da Conceição Ferreira; Massano Cardoso
Journal:  J Bras Pneumol       Date:  2014 May-Jun       Impact factor: 2.624

8.  Volatile Organic Compounds (VOCs) in Conventional and High Performance School Buildings in the U.S.

Authors:  Lexuan Zhong; Feng-Chiao Su; Stuart Batterman
Journal:  Int J Environ Res Public Health       Date:  2017-01-21       Impact factor: 3.390

Review 9.  Monitoring biodiversity in libraries: a pilot study and perspectives for indoor air quality.

Authors:  F Valeriani; C Cianfanelli; G Gianfranceschi; S Santucci; V Romano Spica; N Mucci
Journal:  J Prev Med Hyg       Date:  2017-09

10.  Indoor air quality in Brazilian universities.

Authors:  Sonia R Jurado; Antônia D P Bankoff; Andrea Sanchez
Journal:  Int J Environ Res Public Health       Date:  2014-07-11       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.