Literature DB >> 11419600

Indoor air quality at nine shopping malls in Hong Kong.

W M Li1, S C Lee, L Y Chan.   

Abstract

Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11419600     DOI: 10.1016/s0048-9697(00)00833-0

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  8 in total

1.  Indoor air quality in elementary schools of Lisbon in spring.

Authors:  P N Pegas; C A Alves; M G Evtyugina; T Nunes; M Cerqueira; M Franchi; C A Pio; S M Almeida; M C Freitas
Journal:  Environ Geochem Health       Date:  2010-11-02       Impact factor: 4.609

2.  Radon in indoor concentrations and indoor concentrations of metal dust particles in museums and other public buildings.

Authors:  G L Carneiro; D Braz; E F de Jesus; S M Santos; K Cardoso; A A Hecht; Moore K Dias da Cunha
Journal:  Environ Geochem Health       Date:  2012-11-04       Impact factor: 4.609

3.  Spatial concentration distributions of sulfur dioxide and nitrogen oxides in Patras, Greece, in a winter period.

Authors:  Panayotis C Yannopoulos
Journal:  Environ Monit Assess       Date:  2007-03-07       Impact factor: 2.513

4.  Relationship between indoor air pollutant levels and residential environment in children with atopic dermatitis.

Authors:  Jung Hyun Lee; Ho Seok Lee; Mi Ran Park; Sang Woon Lee; Eun Hye Kim; Joong Bum Cho; Jihyun Kim; Youngshin Han; Kweon Jung; Hae Kwan Cheong; Sang Il Lee; Kangmo Ahn
Journal:  Allergy Asthma Immunol Res       Date:  2014-09-11       Impact factor: 5.764

5.  The correlation of Acanthamoeba from the ventilation system with other environmental parameters in commercial buildings as possible indicator for indoor air quality.

Authors:  Soo Shen Ooi; Joon Wah Mak; Donald K F Chen; Stephen Ambu
Journal:  Ind Health       Date:  2016-07-29       Impact factor: 2.179

6.  High total volatile organic compounds pollution in a hospital dental department.

Authors:  Ming-Hui Liu; Tao-Hsin Tung; Fen-Fang Chung; Li-Chuan Chuang; Gwo-Hwa Wan
Journal:  Environ Monit Assess       Date:  2017-10-18       Impact factor: 2.513

7.  Indoor Air Quality in Tujia Dwellings in Hunan, China: Field Tests, Numerical Simulations, and Mitigation Strategies.

Authors:  Fupeng Zhang; Lei Shi; Simian Liu; Jiaqi Shi; Mengfei Cheng
Journal:  Int J Environ Res Public Health       Date:  2022-07-09       Impact factor: 4.614

8.  Volatile Organic Compounds in Underground Shopping Districts in Korea.

Authors:  Soo Ran Won; Young Sung Ghim; Jeonghoon Kim; Jungmin Ryu; In-Keun Shim; Jongchun Lee
Journal:  Int J Environ Res Public Health       Date:  2021-05-21       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.