Literature DB >> 2099293

Electronic determination of root canal length by newly developed measuring device. Influences of the diameter of apical foramen, the size of K-file and the root canal irrigants.

T Saito1, Y Yamashita.   

Abstract

A new electronic root canal measuring device called "ENDEX" which is able to determine the root canal length under moistened conditions using a relative value of different alternative electric currents is discussed in this study. This study is designed to investigate the efficiencies of the new device, in vitro, with respect to change in the root canal environment; namely the influence of the size of K-file, the diameter of the apical foramen and the various root canal irrigants. According to the present study, it was confirmed that the location of the apical foramen was clearly detected under moistened root canal with saline solution using any size of K-file. The locations of the tip of K-files were 0.5 mm inside the apical foramen when the relative value displayed 0.3 Volt, so that the apical constriction could not disturb during root canal measurement. One of the big problem with prior electrical measurement devices was not being able to determine the canal length under moistened conditions. However with this improved device, intracanal irrigants, such as saline, 5% NaOC1, 14% EDTA and 3% H2O2 did not interfere in detecting apical foramen irregardless of the size of K-file and the size of the apical foramen.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2099293

Source DB:  PubMed          Journal:  Dent Jpn (Tokyo)        ISSN: 0070-3737


  8 in total

1.  Root canal length measurement in teeth with electrolyte compensation.

Authors:  K C Nam; S C Kim; S J Lee; Y J Kim; N G Kim; D W Kim
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  Accuracy of two different apex locators in primary teeth with and without root resorption.

Authors:  Haluk Bodur; Mesut Odabaş; Ozlem Tulunoğlu; Ali Cemal Tinaz
Journal:  Clin Oral Investig       Date:  2007-11-20       Impact factor: 3.573

3.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

4.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

5.  Working Length Determination Using Cone-Beam Computed Tomography, Periapical Radiography and Electronic Apex Locator in Teeth with Apical Periodontitis: A Clinical Study.

Authors:  André Luiz Gomide de Morais; Ana Helena Gonçalves de Alencar; Cyntia Rodrigues de Araújo Estrela; Daniel Almeida Decurcio; Carlos Estrela
Journal:  Iran Endod J       Date:  2016-05-01

6.  Use of artificial primary teeth for endodontic laboratory research: experiments related to canal length determination.

Authors:  Anna Carolina V Mello-Moura; Carmela R Bresolin; Cacio Moura-Netto; André Ito; Angela T Araki; José Carlos P Imparato; Fausto M Mendes
Journal:  BMC Oral Health       Date:  2017-11-17       Impact factor: 2.757

7.  Influence of calcium hydroxide residues after using different irrigants on the accuracy of two electronic apex locators: An in vitro study.

Authors:  Nooshin Sadat Shojaee; Zahra Zaeri; Mohammad Mehdi Shokouhi; Fereshteh Sobhnamayan; Alireza Adl
Journal:  Dent Res J (Isfahan)       Date:  2020-01-21

8.  Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: an ex vivo study.

Authors:  Maayan Shacham; Avi Levin; Avi Shemesh; Alex Lvovsky; Joe Ben Itzhak; Michael Solomonov
Journal:  BDJ Open       Date:  2020-11-17
  8 in total