Literature DB >> 29215150

MRI monitoring of focused ultrasound sonications near metallic hardware.

Hans Weber1, Pejman Ghanouni1, Aurea Pascal-Tenorio1, Kim Butts Pauly1, Brian A Hargreaves1.   

Abstract

PURPOSE: To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware.
METHOD: 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton-resonance-frequency-shift (PRFS) thermometry at different distances from metal devices and different signal-to-noise ratios (SNR).
RESULTS: 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off-resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame.
CONCLUSION: The proposed 2DMSI thermometry has the potential to allow MR-guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259-271, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  focused ultrasound; metallic implants; multi-spectral imaging; proton resonance frequency shift; susceptibility artifact; thermometry

Mesh:

Substances:

Year:  2017        PMID: 29215150      PMCID: PMC5876098          DOI: 10.1002/mrm.27034

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

Review 2.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

3.  Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle.

Authors:  S J Graham; M J Bronskill; R M Henkelman
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

4.  Temperature dependence of proton relaxation times in vitro.

Authors:  T R Nelson; S M Tung
Journal:  Magn Reson Imaging       Date:  1987       Impact factor: 2.546

Review 5.  MR-guided high-intensity focused ultrasound: current status of an emerging technology.

Authors:  Alessandro Napoli; Michele Anzidei; Federica Ciolina; Eugenio Marotta; Beatrice Cavallo Marincola; Giulia Brachetti; Luisa Di Mare; Gaia Cartocci; Fabrizio Boni; Vincenzo Noce; Luca Bertaccini; Carlo Catalano
Journal:  Cardiovasc Intervent Radiol       Date:  2013-03-09       Impact factor: 2.740

6.  Temperature relationships of proton spin-lattice relaxation time T1 in biological tissues.

Authors:  C J Lewa; Z Majewska
Journal:  Bull Cancer       Date:  1980       Impact factor: 1.276

7.  Thermal dose determination in cancer therapy.

Authors:  S A Sapareto; W C Dewey
Journal:  Int J Radiat Oncol Biol Phys       Date:  1984-06       Impact factor: 7.038

8.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age.

Authors:  P A Bottomley; T H Foster; R E Argersinger; L M Pfeifer
Journal:  Med Phys       Date:  1984 Jul-Aug       Impact factor: 4.071

9.  In vivo T2 -based MR thermometry in adipose tissue layers for high-intensity focused ultrasound near-field monitoring.

Authors:  Paul Baron; Mario Ries; Roel Deckers; Martijn de Greef; Jukka Tanttu; Max Köhler; Max A Viergever; Chrit T W Moonen; Lambertus W Bartels
Journal:  Magn Reson Med       Date:  2013-11-20       Impact factor: 4.668

10.  Dual-echo Z-shimmed proton resonance frequency-shift magnetic resonance thermometry near metallic ablation probes: Technique and temperature precision.

Authors:  Yuxin Zhang; Megan E Poorman; William A Grissom
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

View more
  1 in total

Review 1.  New Insights into MR Safety for Implantable Medical Devices.

Authors:  Kagayaki Kuroda; Satoshi Yatsushiro
Journal:  Magn Reson Med Sci       Date:  2022-02-25       Impact factor: 2.760

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.