Literature DB >> 20976407

Evaluation of the linear measurements by conventional radiographs and indirect digital images in the endodontic treatment.

Nicole Kawauchi1, Izabel Regina Fischer Rubira Bullen, Luiz Eduardo Montenegro Chinellato.   

Abstract

INTRODUCTION: A successful endodontic therapy depends on the linear measurements obtained by means of radiographs taken during odontometry and also on the application of the established working length up to the final obturation.
OBJECTIVE: The aim of this study was to compare the precision of the linear measurement obtained by means of conventional radiographs and indirect digital images evaluated by the Digora 1.5 software during the different stages of endodontic treatment, as well as to evaluate the tools available on this software.
METHODS: A total of 160 radiographs of single-rooted teeth were obtained from files, which were analysed and divided in 4 groups comprising odontometry, cone fit, condensation and the final obturation. Analyses of the conventional radiographs and digitized images were performed by five previuosly calibrated examiners.
RESULTS: A high level of inter and intra-examiner agreement was observed through application of the Kendall coefficient and the correlation index, respectively. In relation to the results of linear measurement, the two-way variance analyses and the Tukey test revealed that, concerning the method, a statistically significant decrease was observed on the measurement obtained through the digital method when compared to the conventional radiograph (p<0,05). Moreover, the measurement presented a statistically significant difference among the different stages of endodontic treatment. Regarding interpretation of the digitized image, there was a statistically significant preference towards the Brightness and Contrast tool of the Digora 1.5 software, as evaluated through the Friedman test.
CONCLUSION: The present study demonstrated that image processing by the digital method aids the radiographic interpretation and consequently the determination of reference points for the achievement of the small linear measurements of endodontic treatment. The digital image provided statistically significant smaller linear measurements than those obtained by the conventional method.

Year:  2004        PMID: 20976407     DOI: 10.1590/s1678-77572004000400015

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  2 in total

1.  Perceived quality, clarity, and accuracy of manually processed and self-developing radiographs in endodontics.

Authors:  Emad Alshwaimi; Abdul Majeed
Journal:  Int J Health Sci (Qassim)       Date:  2013-06

Review 2.  Comparative Evaluation of Electronic Apex Locators and Radiovisiography for Working Length Determination in Primary Teeth in vivo.

Authors:  Ahsan Abdullah; Neerja Singh; Monika S Rathore; Shobha Tandon; Balakrishnan Rajkumar
Journal:  Int J Clin Pediatr Dent       Date:  2016-06-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.