Literature DB >> 24421739

Perceived quality, clarity, and accuracy of manually processed and self-developing radiographs in endodontics.

Emad Alshwaimi1, Abdul Majeed1.   

Abstract

OBJECTIVES: To evaluate perceived quality, clarity, and accuracy of self-developing films compared to conventional D- and E-speed manually processed films, and to evaluate their ease of use and satisfaction amongst pre-clinical dental students.
METHODOLOGY: Mesiobuccal root canals of 30 extracted mandibular molar teeth were instrumented and size 10 K-files were glued into the canals at 3 different levels. Each tooth was exposed thrice with the same angulation using conventional E-speed, D-speed, and self-developing films. Conventional films were processed manually and self-developing films according to the manufacturer's instructions, which required 50 seconds of contact time with the solution. Radiographs were evaluated by 4 examiners for quality, clarity, and apical position of the file. A questionnaire-based survey was conducted to evaluate the ease of use, quality, and satisfaction of undergraduate students. Data were analyzed using one-way ANOVA and Tukey-Kramer multiple comparison test, significant at p < 0.05.
RESULTS: The quality and clarity of conventional E-speed films was perceived as significantly better than that of D-speed and self-developing films (p < 0.05). There was no statistically significant difference amongst the 3 film types for recorded file positions (p > 0.05). The results of the student survey corroborated the examiners' views that the self-developing radiographic films were of poor quality.
CONCLUSION: Manually processed E-speed films provided significantly superior quality and clarity of images, but for apical file position, no significant differences were found amongst the 3 film types. Conventional E-speed, D-speed, and self-developing films are all adequate for measuring endodontic working lengths.

Year:  2013        PMID: 24421739      PMCID: PMC3883600          DOI: 10.12816/0006034

Source DB:  PubMed          Journal:  Int J Health Sci (Qassim)        ISSN: 1658-3639


  12 in total

1.  Endodontic measurement accuracy and perceived radiograph quality: effects of film speed and density.

Authors:  J Chris Sheaffer; Paul D Eleazer; James P Scheetz; Stephen J Clark; Allan G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-10

2.  Evaluation of the linear measurements by conventional radiographs and indirect digital images in the endodontic treatment.

Authors:  Nicole Kawauchi; Izabel Regina Fischer Rubira Bullen; Luiz Eduardo Montenegro Chinellato
Journal:  J Appl Oral Sci       Date:  2004-12       Impact factor: 2.698

3.  Comparative analysis of the visualization of small files using digital and conventional radiography.

Authors:  Sandra Regina Boarin Pace; Sandra Márcia Habitante
Journal:  J Appl Oral Sci       Date:  2005-03       Impact factor: 2.698

4.  Clinical investigation of measuring working lengths of root canals with an electronic device and with digital-tactile sense.

Authors:  B H Seidberg; B V Alibrandi; H Fine; B Logue
Journal:  J Am Dent Assoc       Date:  1975-02       Impact factor: 3.634

5.  Radiovisiography versus conventional radiography for detection of small instruments in endodontic length determination. Part 1. In vitro evaluation.

Authors:  M A Ellingsen; G W Harrington; L G Hollender
Journal:  J Endod       Date:  1995-06       Impact factor: 4.171

6.  An evaluation of Ektaspeed Plus film versus Ultraspeed film for endodontic working length determination.

Authors:  R Brown; J N Hadley; D W Chambers
Journal:  J Endod       Date:  1998-01       Impact factor: 4.171

7.  Comparison of radiographic and electronic working lengths.

Authors:  D H Pratten; N J McDonald
Journal:  J Endod       Date:  1996-04       Impact factor: 4.171

8.  A radiographic study of the point of endodontic egress.

Authors:  W N Von der Lehr; R A Marsh
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1973-01

9.  Radiovisiography versus conventional radiography for detection of small instruments in endodontic length determination. II. In vivo evaluation.

Authors:  M A Ellingsen; L G Hollender; G W Harrington
Journal:  J Endod       Date:  1995-10       Impact factor: 4.171

10.  A comparison of D-, E-, and F-speed conventional intraoral radiographic films in endodontic measurement.

Authors:  J Chris Sheaffer; Paul D Eleazer; James P Scheetz; Stephen J Clark; Allan G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2002-03
View more
  1 in total

1.  Comparison of Digital Radiography, Conventional Film and Self-Developing Film for Working Length Determination.

Authors:  Manucher Raees Sameye; Amin Mohammad Bahalkeh; Arash Izadi; Ania Jafaryan
Journal:  Iran Endod J       Date:  2018
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.