Literature DB >> 20975233

Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy.

Takayuki Onishi1, Isshi Kobayashi, Yuko Onishi, Tomoyuki Kawashima, Hirotaka Muramoto, Hiroaki Nakamura, Yasutoshi Nagata, Shigeo Umezawa, Akihiro Niwa.   

Abstract

BACKGROUND: Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. METHODS AND
RESULTS: The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP SPECT 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001).
CONCLUSIONS: 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20975233     DOI: 10.1253/circj.cj-10-0532

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  3 in total

1.  Pacemaker malfunction after acute myocardial infarction in a patient with wrap-around left anterior descending artery supplying the right ventricular apex.

Authors:  Tomohiko C Umei; Toru Awaya; Osamu Okazaki; Hisao Hara; Yukio Hiroi
Journal:  J Cardiol Cases       Date:  2018-04-04

2.  Comparison of LDPI to SPECT perfusion imaging using (99m)Tc-sestamibi and (99m)Tc-pyrophosphate in a murine ischemic hind limb model of neovascularization.

Authors:  Geert Hendrikx; Mark H Vries; Matthias Bauwens; Marijke De Saint-Hubert; Allard Wagenaar; Joël Guillaume; Levinia Boonen; Mark J Post; Felix M Mottaghy
Journal:  EJNMMI Res       Date:  2016-05-27       Impact factor: 3.138

Review 3.  SPECT and PET imaging of angiogenesis and arteriogenesis in pre-clinical models of myocardial ischemia and peripheral vascular disease.

Authors:  Geert Hendrikx; Stefan Vöö; Matthias Bauwens; Mark J Post; Felix M Mottaghy
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-12       Impact factor: 9.236