Literature DB >> 11567578

High spatial resolution multi-site EPR oximetry. The use of convolution-based fitting method.

O Y Grinberg1, A I Smirnov, H M Swartz.   

Abstract

We describe a new method to enhance the spatial resolution of multi-site electron paramagnetic resonance (EPR) oximetry. The method is suitable for any shape (density distribution function) of a solid paramagnetic material implanted in tissue. It corrects distortions of lineshapes caused by the gradient and thus overcomes limitations of previous multi-site EPR oximetry methods that restricted the ratio of the particle size to the distance between sites. The new method is based on consecutive applications of magnetic field gradients with the same direction but with a different magnitude and uses a convolution-based fitting algorithm to derive Lorentzian EPR linewidths of each individual peak of the EPR spectrum. The method is applicable for any particulate EPR oxygen sensitive materials whose EPR spectra can be approximated by a Lorentzian function or a superposition of Lorentzian functions. By incorporating this model of the lineshape in the data processing, we are able to decrease significantly the number of parameters needed for the calculations and to recover the oxygen concentration, even from quite noisy spectra. We (i) describe our method and the data-processing algorithm, (ii) demonstrate our approach in model and in vivo experiments, and (iii) discuss the limitations. Copyright 2001 Academic Press.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11567578     DOI: 10.1006/jmre.2001.2408

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  16 in total

1.  Repeated assessment of orthotopic glioma pO(2) by multi-site EPR oximetry: a technique with the potential to guide therapeutic optimization by repeated measurements of oxygen.

Authors:  Nadeem Khan; Sriram Mupparaju; Huagang Hou; Benjamin B Williams; Harold Swartz
Journal:  J Neurosci Methods       Date:  2011-11-04       Impact factor: 2.390

2.  Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy.

Authors:  R Ahmad; S Som; E Kesselring; P Kuppusamy; J L Zweier; L C Potter
Journal:  J Magn Reson       Date:  2010-09-29       Impact factor: 2.229

Review 3.  Repetitive tissue pO2 measurements by electron paramagnetic resonance oximetry: current status and future potential for experimental and clinical studies.

Authors:  Nadeem Khan; Benjamin B Williams; Huagang Hou; Hongbin Li; Harold M Swartz
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

4.  EPR oximetry in three spatial dimensions using sparse spin distribution.

Authors:  Subhojit Som; Lee C Potter; Rizwan Ahmad; Deepti S Vikram; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2008-05-14       Impact factor: 2.229

5.  Estimation of mean and median pO2 values for a composite EPR spectrum.

Authors:  Rizwan Ahmad; Deepti S Vikram; Lee C Potter; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2008-03-10       Impact factor: 2.229

6.  Compressed sensing of spatial electron paramagnetic resonance imaging.

Authors:  David H Johnson; Rizwan Ahmad; Guanglong He; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

Review 7.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

Review 8.  Measurements in vivo of parameters pertinent to ROS/RNS using EPR spectroscopy.

Authors:  Nadeem Khan; Harold Swartz
Journal:  Mol Cell Biochem       Date:  2002 May-Jun       Impact factor: 3.396

Review 9.  Clinical EPR: unique opportunities and some challenges.

Authors:  Harold M Swartz; Benjamin B Williams; Bassem I Zaki; Alan C Hartford; Lesley A Jarvis; Eunice Y Chen; Richard J Comi; Marc S Ernstoff; Huagang Hou; Nadeem Khan; Steven G Swarts; Ann B Flood; Periannan Kuppusamy
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

10.  Application of in vivo EPR for tissue pO2 and redox measurements.

Authors:  Nadeem Khan; Dipak K Das
Journal:  Methods Mol Biol       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.