Literature DB >> 20965908

Design and construction of a multipath vessel phantom for interventional training.

Y Thakur1, H N Nikolov, I B Gulka, D W Holdsworth, M Drangova.   

Abstract

This short communication reports on the design and construction of a catheter manipulation skill enhancement phantom for use by residents and fellows outside the clinical environment. The phantom contains a variety of path trajectories and vessel diameter transitions, allowing trainees to manipulate catheters through vessel paths of varying difficulty. The multipath phantom, which is easy to construct and provides easily visualised paths, provides a simple, cost-effective training platform to facilitate and accelerate interventional training.

Entities:  

Mesh:

Year:  2010        PMID: 20965908      PMCID: PMC3473736          DOI: 10.1259/bjr/91767642

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  15 in total

1.  Vascular guide wire navigation with a magnetic guidance system: experimental results in a phantom.

Authors:  Mirko Schiemann; Reinmar Killmann; Martin Kleen; Nasreddin Abolmaali; Jennifer Finney; Thomas J Vogl
Journal:  Radiology       Date:  2004-06-23       Impact factor: 11.105

2.  A thin-walled carotid vessel phantom for Doppler ultrasound flow studies.

Authors:  Tamie L Poepping; Hristo N Nikolov; Meghan L Thorne; David W Holdsworth
Journal:  Ultrasound Med Biol       Date:  2004-08       Impact factor: 2.998

3.  Multisite trial of MR flow measurement: phantom and protocol design.

Authors:  Paul E Summers; David W Holdsworth; Hristo N Nikolov; Brian K Rutt; Maria Drangova
Journal:  J Magn Reson Imaging       Date:  2005-05       Impact factor: 4.813

4.  Generating an ex vivo vascular model.

Authors:  Padraig M O'Flynn; Ellen T Roche; Abhay S Pandit
Journal:  ASAIO J       Date:  2005 Jul-Aug       Impact factor: 2.872

5.  A randomised controlled study comparing conventional and magnetic guidewires in a two-dimensional branching tortuous phantom simulating angulated coronary vessels.

Authors:  Steve Ramcharitar; Mark S Patterson; Robert J van Geuns; Martin van der Ent; Georgios Sianos; Gijs M J M Welten; Ron T van Domburg; Patrick W Serruys
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-01       Impact factor: 2.692

6.  The role of simulation in training endovascular interventions.

Authors:  D A Gould; J A Reekers
Journal:  Eur J Vasc Endovasc Surg       Date:  2008-03-03       Impact factor: 7.069

7.  Multimodality vascular imaging phantoms: a new material for the fabrication of realistic 3D vessel geometries.

Authors:  Louise Allard; Gilles Soulez; Boris Chayer; François Treyve; Zhao Qin; Guy Cloutier
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

8.  Magnetic navigation in a coronary phantom: experimental results.

Authors:  Héctor M García-García; Keiichi Tsuchida; Hans Meulenbrug; Andrew T L Ong; Willem J Van der Giessen; Patrick W Serruys
Journal:  EuroIntervention       Date:  2005-11       Impact factor: 6.534

9.  A geometrically accurate vascular phantom for comparative studies of x-ray, ultrasound, and magnetic resonance vascular imaging: construction and geometrical verification.

Authors:  R Frayne; L M Gowman; D W Rickey; D W Holdsworth; P A Picot; M Drangova; K C Chu; C B Caldwell; A Fenster; B K Rutt
Journal:  Med Phys       Date:  1993 Mar-Apr       Impact factor: 4.071

10.  Carotid artery distensibility: a reliability study.

Authors:  Elisa Cuadrado Godia; Rishi Madhok; John Pittman; Samuel Trocio; Romel Ramas; Digna Cabral; Ralph L Sacco; Tatjana Rundek
Journal:  J Ultrasound Med       Date:  2007-09       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.