PURPOSE: To investigate the effect of the bronchial tree on the accuracy of biomechanical-based deformable image registration of human lungs.
METHODS: Three dimensional finite element models have been developed using four dimensional computed tomography image data of ten lung cancer patients. Each model is built of a body, left and right lungs, tumor, and bronchial trees. Triangular shell elements are used for the bronchial trees while tetrahedral elements are used for other components. Hyperelastic material properties based on experimental investigation on human lungs are used for the lung parenchyma. Different material properties are assigned for the bronchial tree using five values for the modulus of elasticity of 0.01, 0.12, 0.5, 10, and 18 MPa. Lungs are modeled to slide inside chest cavities by applying frictionless contact surfaces between each lung and corresponding chest cavity. The accuracy of the models is examined using an average of 40 bronchial bifurcation points identified on inhale and exhale images. Relative accuracy is evaluated by comparing the displacement of all nodes within the lungs as well as the dosimetric difference at the exhale position predicted by the model.
RESULTS: There is no significant effect of bronchial tree on the model accuracy based on the bifurcation points analysis. However, on the local level, using an average of 38 000 nodes, there is a maximum difference of 8.5 mm in the deformation of the bronchial trees, as the modulus of elasticity of the bronchial trees increases from 0.01 to 18 MPa; however, more than 96% of nodes are within a 2.5 mm difference in each direction. The average dose difference at the predicted exhale position is less than 35 cGy between the models.
CONCLUSIONS: The bronchial tree has little effect on the global deformation and the accuracy of deformable image registration of lungs. Hence, the homogenous model is a reasonable assumption. Since there are some local deformation differences between nodes as the material properties of the bronchial tree change that may affect the accuracy of dosimetric results, heterogeneity may be required for a smaller scale modeling of lungs.

Entities:  

Mesh:

Year:  2010        PMID: 20964173      PMCID: PMC2933251          DOI: 10.1118/1.3471020

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  35 in total

1.  A method for estimating the Young's modulus of complete tracheal cartilage rings.

Authors:  R K Lambert; E M Baile; R Moreno; J Bert; P D Paré
Journal:  J Appl Physiol (1985)       Date:  1991-03

Review 2.  Non-rigid image registration: theory and practice.

Authors:  W R Crum; T Hartkens; D L G Hill
Journal:  Br J Radiol       Date:  2004       Impact factor: 3.039

3.  Accuracy of finite element model-based multi-organ deformable image registration.

Authors:  K K Brock; M B Sharpe; L A Dawson; S M Kim; D A Jaffray
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

Review 4.  Computer analysis of computed tomography scans of the lung: a survey.

Authors:  Ingrid Sluimer; Arnold Schilham; Mathias Prokop; Bram van Ginneken
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

5.  Measurement of the mechanical properties of the human lung tissue.

Authors:  Y J Zeng; D Yager; Y C Fung
Journal:  J Biomech Eng       Date:  1987-05       Impact factor: 2.097

6.  A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy.

Authors:  Jamie R McClelland; Jane M Blackall; Ségolène Tarte; Adam C Chandler; Simon Hughes; Shahreen Ahmad; David B Landau; David J Hawkes
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

7.  Airway geometry and wall mechanical properties estimated from subglottal input impedance in humans.

Authors:  R H Habib; R B Chalker; B Suki; A C Jackson
Journal:  J Appl Physiol (1985)       Date:  1994-07

8.  Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines.

Authors:  Martha M Coselmon; James M Balter; Daniel L McShan; Marc L Kessler
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

9.  A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models.

Authors:  Y Chi; J Liang; D Yan
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

10.  Mechanical properties of human tracheal cartilage.

Authors:  J K Rains; J L Bert; C R Roberts; P D Paré
Journal:  J Appl Physiol (1985)       Date:  1992-01
View more
  11 in total

1.  A hybrid biomechanical intensity based deformable image registration of lung 4DCT.

Authors:  Navid Samavati; Michael Velec; Kristy Brock
Journal:  Phys Med Biol       Date:  2015-04-01       Impact factor: 3.609

2.  Biomechanical deformable image registration of longitudinal lung CT images using vessel information.

Authors:  Guillaume Cazoulat; Dawn Owen; Martha M Matuszak; James M Balter; Kristy K Brock
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

3.  Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy.

Authors:  Adil Al-Mayah; Joanne Moseley; Mike Velec; Kristy Brock
Journal:  Phys Med Biol       Date:  2011-07-06       Impact factor: 3.609

4.  4D liver tumor localization using cone-beam projections and a biomechanical model.

Authors:  You Zhang; Michael R Folkert; Bin Li; Xiaokun Huang; Jeffrey J Meyer; Tsuicheng Chiu; Pam Lee; Joubin Nasehi Tehrani; Jing Cai; David Parsons; Xun Jia; Jing Wang
Journal:  Radiother Oncol       Date:  2018-11-14       Impact factor: 6.280

5.  Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters.

Authors:  Joubin Nasehi Tehrani; Yin Yang; Rene Werner; Wei Lu; Daniel Low; Xiaohu Guo; Jing Wang
Journal:  Phys Med Biol       Date:  2015-11-04       Impact factor: 3.609

6.  Enhancing liver tumor localization accuracy by prior-knowledge-guided motion modeling and a biomechanical model.

Authors:  You Zhang; Michael R Folkert; Xiaokun Huang; Lei Ren; Jeffrey Meyer; Joubin Nasehi Tehrani; Robert Reynolds; Jing Wang
Journal:  Quant Imaging Med Surg       Date:  2019-07

7.  A hybrid, image-based and biomechanics-based registration approach to markerless intraoperative nodule localization during video-assisted thoracoscopic surgery.

Authors:  Pablo Alvarez; Simon Rouzé; Michael I Miga; Yohan Payan; Jean-Louis Dillenseger; Matthieu Chabanas
Journal:  Med Image Anal       Date:  2021-01-30       Impact factor: 13.828

8.  Rapid Automated Target Segmentation and Tracking on 4D Data without Initial Contours.

Authors:  Venkata V Chebrolu; Daniel Saenz; Dinesh Tewatia; William A Sethares; George Cannon; Bhudatt R Paliwal
Journal:  Radiol Res Pract       Date:  2014-08-03

9.  Evaluation of accuracy of B-spline transformation-based deformable image registration with different parameter settings for thoracic images.

Authors:  Takayuki Kanai; Noriyuki Kadoya; Kengo Ito; Yusuke Onozato; Sang Yong Cho; Kazuma Kishi; Suguru Dobashi; Rei Umezawa; Haruo Matsushita; Ken Takeda; Keiichi Jingu
Journal:  J Radiat Res       Date:  2014-07-22       Impact factor: 2.724

10.  Validation of nonrigid registration in pretreatment and follow-up PET/CT scans for quantification of tumor residue in lung cancer patients.

Authors:  Jolanda Spijkerman; Davide Fontanarosa; Marco Das; Wouter Van Elmpt
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.