Literature DB >> 20960583

Three-dimensional T1 mapping of the mouse heart using variable flip angle steady-state MR imaging.

Bram F Coolen1, Tessa Geelen, Leonie E M Paulis, Arno Nauerth, Klaas Nicolay, Gustav J Strijkers.   

Abstract

Cardiac MR T(1) mapping is a promising quantitative imaging tool for the diagnosis and evaluation of cardiomyopathy. Here, we present a new preclinical cardiac MRI method enabling three-dimensional T(1) mapping of the mouse heart. The method is based on a variable flip angle analysis of steady-state MR imaging data. A retrospectively triggered three-dimensional FLASH (fast low-angle shot) sequence (3D IntraGate) enables a constant repetition time and maintains steady-state conditions. 3D T(1) mapping of the complete mouse heart could be achieved in 20 min. High-quality, bright-blood T(1) maps were obtained with homogeneous T(1) values (1764 ± 172 ms) throughout the myocardium. The repeatability coefficient of R(1) (1/T(1) ) in a specific region of the mouse heart was between 0.14 and 0.20 s(-1) , depending on the number of flip angles. The feasibility for detecting regional differences in ΔR(1) was shown with pre- and post-contrast T(1) mapping in mice with surgically induced myocardial infarction, for which ΔR(1) values up to 0.83 s(-1) were found in the infarct zone. The sequence was also investigated in black-blood mode, which, interestingly, showed a strong decrease in the apparent mean T(1) of healthy myocardium (905 ± 110 ms). This study shows that 3D T(1) mapping in the mouse heart is feasible and can be used to monitor regional changes in myocardial T(1), particularly in relation to pathology and in contrast-enhanced experiments to estimate local concentrations of (targeted) contrast agent.
Copyright © 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20960583     DOI: 10.1002/nbm.1566

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  21 in total

1.  Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

Authors:  Sebastian Weingärtner; Nadja M Meßner; Frank G Zöllner; Mehmet Akçakaya; Lothar R Schad
Journal:  Magn Reson Med       Date:  2016-09-16       Impact factor: 4.668

Review 2.  Magnetic resonance imaging and spectroscopy of the murine cardiovascular system.

Authors:  Ashwin Akki; Ashish Gupta; Robert G Weiss
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-01-04       Impact factor: 4.733

3.  Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

Authors:  Sebastian Weingärtner; Fabian Zimmer; Gregory J Metzger; Kâmil Uğurbil; Pierre-Francois Van de Moortele; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2016-09-07       Impact factor: 4.668

4.  Manganese-enhanced MRI detection of impaired calcium regulation in a mouse model of cardiac hypertrophy.

Authors:  Martin Andrews; Maryellen L Giger; Brian B Roman
Journal:  NMR Biomed       Date:  2014-12-19       Impact factor: 4.044

5.  Novel contrast mixture achieves contrast resolution of human bladder wall suitable for T1 mapping: applications in interstitial cystitis and beyond.

Authors:  Pradeep Tyagi; Joseph Janicki; Chan-Hong Moon; Jonathan Kaufman; Christopher Chermansky
Journal:  Int Urol Nephrol       Date:  2018-02-01       Impact factor: 2.370

6.  Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

Authors:  Sebastian Weingärtner; Mehmet Akçakaya; Sébastien Roujol; Tamer Basha; Christian Stehning; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02-05       Impact factor: 4.668

7.  Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T1 mapping using a cine steady-state look-locker approach.

Authors:  Sebastian Weingärtner; Chetan Shenoy; Benedikt Rieger; Lothar R Schad; Jeanette Schulz-Menger; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

8.  Comparison of echocardiographic measurements of left ventricular volumes to full volume magnetic resonance imaging in normal and diseased rats.

Authors:  Teresa Arias; Jiqiu Chen; Zahi A Fayad; Valentin Fuster; Roger J Hajjar; Elie R Chemaly
Journal:  J Am Soc Echocardiogr       Date:  2013-05-23       Impact factor: 5.251

9.  Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE.

Authors:  Sébastien Roujol; Sebastian Weingärtner; Murilo Foppa; Kelvin Chow; Keigo Kawaji; Long H Ngo; Peter Kellman; Warren J Manning; Richard B Thompson; Reza Nezafat
Journal:  Radiology       Date:  2014-04-04       Impact factor: 11.105

Review 10.  Cellular pathology of the human heart in Duchenne muscular dystrophy (DMD): lessons learned from in vitro modeling.

Authors:  Albano C Meli; Vladimir Rotrekl; Barbora Svobodova; Sarka Jelinkova; Martin Pesl; Deborah Beckerová; Alain Lacampagne
Journal:  Pflugers Arch       Date:  2021-06-24       Impact factor: 3.657

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.