Literature DB >> 20946555

Identification of gender-related normality regions for T-wave alternans.

Laura Burattini1, Wojciech Zareba, Roberto Burattini.   

Abstract

BACKGROUND: T-wave alternans (TWA), a harbinger of sudden cardiac death, associates to a broad variety of pathologies. In a previous study, we observed the presence of unstable and low-amplitude TWA also in healthy subjects, and considered it as "physiological TWA." The possible existence of different TWA characteristics between males and female is investigated in the present work.
METHODS: Resting ECG recordings from 142 control healthy subjects, 77 males and 65 females, were submitted to our adaptive match filter (AMF) based method for TWA detection and characterization in terms of duration, amplitude, and their product. The 99.5th percentile of these parameters distributions over the entire control population and over the male and female subgroups, were used to define thresholds which delimit a gender-independent and male- and female-related TWA normality regions, respectively, out of which abnormal TWA cases (TWA+) are expected to fall. Clinical usefulness of these regions was tested using a population of 151 coronary artery disease (CAD) patients, divided into 128 males and 23 females.
RESULTS: In our control-female population, TWA duration was significantly longer than in control-male population (65 ± 13 beat vs 52 ± 14 beat; P < 10(-6) ). Our gender-related normality regions allowed identification of 36 (23.8%) TWA+ cases among the CAD patients, 17 more than those obtained from a gender-independent region. All these 17 patients were CAD males with over-threshold TWA duration.
CONCLUSIONS: TWA is a gender-related phenomenon. Definition of gender-related TWA normality regions improves identification of patients at increased TWA stability (i.e., prolonged TWA duration) and, thus, at increased risk of arrhythmic events. ©2010, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20946555      PMCID: PMC3124337          DOI: 10.1111/j.1542-474X.2010.00388.x

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  23 in total

1.  Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy.

Authors:  Bruce D Nearing; Richard L Verrier
Journal:  J Appl Physiol (1985)       Date:  2002-02

2.  Role of calcium cycling versus restitution in the mechanism of repolarization alternans.

Authors:  Etienne J Pruvot; Rodolphe P Katra; David S Rosenbaum; Kenneth R Laurita
Journal:  Circ Res       Date:  2004-03-11       Impact factor: 17.367

3.  Dynamic tracking of cardiac vulnerability by complex demodulation of the T wave.

Authors:  B D Nearing; A H Huang; R L Verrier
Journal:  Science       Date:  1991-04-19       Impact factor: 47.728

4.  Adaptive match filter based method for time vs. amplitude characterization of microvolt ECG T-wave alternans.

Authors:  Laura Burattini; Wojciech Zareba; Roberto Burattini
Journal:  Ann Biomed Eng       Date:  2008-07-10       Impact factor: 3.934

5.  Microvolt T-wave alternans and the risk of death or sustained ventricular arrhythmias in patients with left ventricular dysfunction.

Authors:  Daniel M Bloomfield; J Thomas Bigger; Richard C Steinman; Pearila B Namerow; Michael K Parides; Anne B Curtis; Elizabeth S Kaufman; Jorge M Davidenko; Timothy S Shinn; John M Fontaine
Journal:  J Am Coll Cardiol       Date:  2005-12-15       Impact factor: 24.094

6.  Comparative analysis of methods for automatic detection and quantification of microvolt T-wave alternans.

Authors:  Laura Burattini; Silvia Bini; Roberto Burattini
Journal:  Med Eng Phys       Date:  2009-09-15       Impact factor: 2.242

7.  Electrical alternans and cardiac electrical instability.

Authors:  J M Smith; E A Clancy; C R Valeri; J N Ruskin; R J Cohen
Journal:  Circulation       Date:  1988-01       Impact factor: 29.690

8.  Effect of oral beta-blocker therapy on microvolt T-wave alternans and electrophysiology testing in patients with ischemic cardiomyopathy.

Authors:  Eran S Zacks; Daniel P Morin; Shaun Ageno; Matthew Janik; Andreas C Mauer; Steven M Markowitz; Suneet Mittal; Sei Iwai; Bindi K Shah; Bruce B Lerman; Kenneth M Stein
Journal:  Am Heart J       Date:  2007-03       Impact factor: 4.749

9.  Fluctuations in T-wave morphology and susceptibility to ventricular fibrillation.

Authors:  D R Adam; J M Smith; S Akselrod; S Nyberg; A O Powell; R J Cohen
Journal:  J Electrocardiol       Date:  1984-07       Impact factor: 1.438

10.  Quantification of ischaemia induced vulnerability by precordial T wave alternans analysis in dog and human.

Authors:  B D Nearing; S N Oesterle; R L Verrier
Journal:  Cardiovasc Res       Date:  1994-09       Impact factor: 10.787

View more
  4 in total

1.  Comparison of standard versus orthogonal ECG leads for T-wave alternans identification.

Authors:  Laura Burattini; Sumche Man; Roberto Burattini; Cees A Swenne
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-04       Impact factor: 1.468

2.  The Telemetric and Holter ECG Warehouse (THEW): the first three years of development and research.

Authors:  Jean-Philippe Couderc
Journal:  J Electrocardiol       Date:  2012-09-28       Impact factor: 1.438

3.  Heart Rate-Dependent Hysteresis of T-Wave Alternans in Primary Prevention ICD Patients.

Authors:  Laura Burattini; Sumche Man; Sandro Fioretti; Francesco Di Nardo; Cees A Swenne
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-12-16       Impact factor: 1.468

4.  T-Wave Alternans in Nonpathological Preterm Infants.

Authors:  Ilaria Marcantoni; Agnese Sbrollini; Gloria Agostinelli; Francesca Chiara Surace; Massimo Colaneri; Micaela Morettini; Marco Pozzi; Laura Burattini
Journal:  Ann Noninvasive Electrocardiol       Date:  2020-01-27       Impact factor: 1.468

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.