Literature DB >> 20941756

Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: systematic investigation using ultra-high-performance liquid chromatography/mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization.

Daniela Remane1, Markus R Meyer, Dirk K Wissenbach, Hans H Maurer.   

Abstract

In multi-analyte procedures, sufficient separation is important to avoid interferences, particularly when using liquid chromatography/mass spectrometry (LC/MS) because of possible ion suppression or enhancement. However, even using ultra-high-performance LC, baseline separation is not always possible. For development and validation of an LC/MS/MS approach for quantification of 140 antidepressants, benzodiazepines, neuroleptics, beta-blockers, oral antidiabetics, and analytes measured in the context of brain death diagnosis in plasma, the extent of ion suppression or enhancement of co-eluting analytes within and between the drug classes was investigated using atmospheric-pressure chemical ionization (APCI) or electrospray ionization (ESI). Within the drug classes, five analytes showed ion enhancement of over 25% and six analytes ion suppression of over 25% using APCI and 16 analytes ion suppression of over 25% using ESI. Between the drug classes, two analytes showed ion suppression of over 25% using APCI. Using ESI, one analyte showed ion enhancement of over 25% and five analytes ion suppression of over 25%. These effects may influence the drug quantification using calibrators made in presence of overlapping and thus interfering analytes. Ion suppression/enhancement effects induced by co-eluting drugs of different classes present in the patient sample may also lead to false measurements using class-specific calibrators made in absence of overlapping and thus interfering analytes. In conclusion, ion suppression and enhancement tests are essential during method development and validation in LC/MS/MS multi-analyte procedures, with special regards to co-eluting analytes.
Copyright © 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20941756     DOI: 10.1002/rcm.4736

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  7 in total

1.  Alternative calibration strategies for the clinical laboratory: application to nortriptyline therapeutic drug monitoring.

Authors:  Matthew T Olson; Autumn Breaud; Robert Harlan; Nkechinyere Emezienna; Sabitha Schools; Alfred L Yergey; William Clarke
Journal:  Clin Chem       Date:  2013-02-20       Impact factor: 8.327

2.  Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma.

Authors:  Rachel E Kopec; Ralf M Schweiggert; Ken M Riedl; Reinhold Carle; Steven J Schwartz
Journal:  Rapid Commun Mass Spectrom       Date:  2013-06-30       Impact factor: 2.419

3.  Quantitative LC-MS/MS Analysis of Proteins Involved in Metastasis of Breast Cancer.

Authors:  Rieko Goto; Yasushi Nakamura; Tomonori Takami; Tokio Sanke; Zenzaburo Tozuka
Journal:  PLoS One       Date:  2015-07-15       Impact factor: 3.240

4.  A complex matrix characterization approach, applied to cigarette smoke, that integrates multiple analytical methods and compound identification strategies for non-targeted liquid chromatography with high-resolution mass spectrometry.

Authors:  Daniel Arndt; Christian Wachsmuth; Christoph Buchholz; Mark Bentley
Journal:  Rapid Commun Mass Spectrom       Date:  2020-01-30       Impact factor: 2.419

5.  Simultaneous determination of phenolic acids by UPLC-MS/MS in rat plasma and its application in pharmacokinetic study after oral administration of Flos Lonicerae preparations.

Authors:  Wei Zhou; Shijia Liu; Wenzheng Ju; Jinjun Shan; Minxin Meng; Baochang Cai; Liuqing Di
Journal:  J Pharm Biomed Anal       Date:  2013-08-17       Impact factor: 3.935

6.  Liquid Chromatography-High-Resolution Mass Spectrometry-Based In Vitro Toxicometabolomics of the Synthetic Cathinones 4-MPD and 4-MEAP in Pooled Human Liver Microsomes.

Authors:  Sascha K Manier; Florian Schwermer; Lea Wagmann; Niels Eckstein; Markus R Meyer
Journal:  Metabolites       Date:  2020-12-23

7.  Non-targeted and targeted analysis of oxylipins in combination with charge-switch derivatization by ion mobility high-resolution mass spectrometry.

Authors:  Stefan Hellhake; Sven W Meckelmann; Michael T Empl; Kristina Rentmeister; Walter Wißdorf; Pablo Steinberg; Oliver J Schmitz; Thorsten Benter; Nils Helge Schebb
Journal:  Anal Bioanal Chem       Date:  2020-07-22       Impact factor: 4.142

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.