Literature DB >> 20938070

Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing.

Timothy P Szczykutowicz1, Guang-Hong Chen.   

Abstract

Dual energy computed tomography (DECT) is currently a subject of extensive investigation. DECT is currently implemented using either a dual source scanner with high and low kVp data acquired from separate sources or a single source scanner with both high and low kVp data acquired in an alternating manner. Both methods require dedicated hardware to enable data acquisition and image reconstruction for DECT. In this paper, we present a method to enable DECT using a single x-ray source with a slow kVp switching data acquisition. The enabling reconstruction technique allowing for the reduction in slew rate is the prior image constrained compressed sensing (PICCS) algorithm. When a slow kVp switching data acquisition method is used, the projection data with high and low kVp values are undersampled and the conventional filtered backprojection (FBP) image reconstruction does not enable streaking artifact-free images for material decomposition in DECT. In this paper, all of the acquired high and low kVp projection data were used to generate a prior image using the conventional FBP method. The PICCS algorithm was then used to reconstruct both high and low kVp images to enable material decomposition in the image domain. Both numerical simulations and physical phantom experimental studies were conducted to validate the proposed DECT scheme. The results demonstrate that a slew rate corresponding to 123 views at high and low kVp (high and low kVp values used for dual energy decomposition) is sufficient for the PICCS-based DECT method. In contrast, the slew rate should be high enough to obtain over 500 projections at each kVp for artifact-free reconstruction using an FBP-based DECT method.

Mesh:

Year:  2010        PMID: 20938070     DOI: 10.1088/0031-9155/55/21/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

5.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Dual-energy cone-beam CT with a flat-panel detector: effect of reconstruction algorithm on material classification.

Authors:  W Zbijewski; G J Gang; J Xu; A S Wang; J W Stayman; K Taguchi; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

Review 7.  Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations.

Authors:  Shima Aran; Khalid W Shaqdan; Hani H Abujudeh
Journal:  Emerg Radiol       Date:  2014-03-28

8.  Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

Authors:  Houjin Zhang; Dong Zeng; Jiahui Lin; Hao Zhang; Zhaoying Bian; Jing Huang; Yuanyuan Gao; Shanli Zhang; Hua Zhang; Qianjin Feng; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  Phys Med Biol       Date:  2017-05-04       Impact factor: 3.609

9.  Spectral CT Reconstruction with Image Sparsity and Spectral Mean.

Authors:  Yi Zhang; Yan Xi; Qingsong Yang; Wenxiang Cong; Jiliu Zhou; Ge Wang
Journal:  IEEE Trans Comput Imaging       Date:  2016-09-14

10.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.