Literature DB >> 2092815

Digital chest imaging using a 57-cm image intensifier: a receiver-operating characteristic study of user performance.

G W Brauer1, P D Fisher, D B Pengelly, G W Ritchie.   

Abstract

Chest radiography provides one of the great challenges to digital diagnostic imaging because of (1) the relatively large size of the chest field, (2) the contrast range required to resolve subtle pathological changes in soft tissue density, and (3) the high degree of spatial resolution required to discriminate pathological detail. The field size problem was resolved by using a 57-cm image intensifier whose video output of the chest could be digitized. The issue of contrast resolution was addressed in a recently completed receiver-operating characteristic study of the detectability of low-contrast densities in a humanoid chest phantom. The latter indicated that, despite the smaller size of the digital image, they were adequate for resolving clinically significant soft-tissue densities. The question of spatial resolution in digital diagnostic images is addressed in the study presented. A set of 41 clinical cases were selected to provide the typical range of diagnostic type experienced in routine diagnostic radiology. The images were each presented as conventional film, digital laser-printer, and digital video images. The results of an ROC analysis of five readers' performance in each of the viewing modes is presented.

Mesh:

Year:  1990        PMID: 2092815     DOI: 10.1007/BF03170568

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  4 in total

1.  Impact of image size on effectiveness of digital imaging systems.

Authors:  P D Fisher; G W Brauer
Journal:  J Digit Imaging       Date:  1989-02       Impact factor: 4.056

2.  Signal detection in digital chest-phantom images acquired with an image intensifier.

Authors:  G W Brauer; P D Fisher; J A Hanley; G W Ritchie
Journal:  J Digit Imaging       Date:  1989-02       Impact factor: 4.056

3.  Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats.

Authors:  H MacMahon; C E Metz; K Doi; T Kim; M L Giger; H P Chan
Journal:  Radiology       Date:  1988-09       Impact factor: 11.105

4.  Digital projection radiography of the chest.

Authors:  H L Kundel
Journal:  Radiology       Date:  1986-01       Impact factor: 11.105

  4 in total
  1 in total

Review 1.  Literature review: picture archiving and communication system.

Authors:  U P Schmiedl; A H Rowberg
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.