BACKGROUND: Estimation of the magnitude and duration of effects of carbohydrate (CHO) and subcutaneously administered insulin on blood glucose (BG) is required for improved BG regulation in people with type 1 diabetes mellitus (T1DM). The goal of this study was to quantify these effects in people with T1DM using a novel protocol. METHODS: The protocol duration was 8 hours: a 1-3 U subcutaneous (SC) insulin bolus was administered and a 25-g CHO meal was consumed, with these inputs separated by 3-5 hours. The DexCom SEVEN® PLUS continuous glucose monitor was used to obtain SC glucose measurements every 5 minutes and YSI 2300 Stat Plus was used to obtain intravenous glucose measurements every 15 minutes. RESULTS: The protocol was tested on 11 subjects at Sansum Diabetes Research Institute. The intersubject parameter coefficient of variation for the best identification method was 170%. The mean percentages of output variation explained by the bolus insulin and meal models were 68 and 69%, respectively, with root mean square error of 14 and 10 mg/dl, respectively. Relationships between the model parameters and clinical parameters were observed. CONCLUSION: Separation of insulin boluses and meals in time allowed unique identification of model parameters. The wide intersubject variation in parameters supports the notion that glucose-insulin models and thus insulin delivery algorithms for people with T1DM should be personalized. This experimental protocol could be used to refine estimates of the correction factor and the insulin-to-carbohydrate ratio used by people with T1DM.
BACKGROUND: Estimation of the magnitude and duration of effects of carbohydrate (CHO) and subcutaneously administered insulin on blood glucose (BG) is required for improved BG regulation in people with type 1 diabetes mellitus (T1DM). The goal of this study was to quantify these effects in people with T1DM using a novel protocol. METHODS: The protocol duration was 8 hours: a 1-3 U subcutaneous (SC) insulin bolus was administered and a 25-g CHO meal was consumed, with these inputs separated by 3-5 hours. The DexCom SEVEN® PLUS continuous glucose monitor was used to obtain SC glucose measurements every 5 minutes and YSI 2300 Stat Plus was used to obtain intravenous glucose measurements every 15 minutes. RESULTS: The protocol was tested on 11 subjects at Sansum Diabetes Research Institute. The intersubject parameter coefficient of variation for the best identification method was 170%. The mean percentages of output variation explained by the bolus insulin and meal models were 68 and 69%, respectively, with root mean square error of 14 and 10 mg/dl, respectively. Relationships between the model parameters and clinical parameters were observed. CONCLUSION: Separation of insulin boluses and meals in time allowed unique identification of model parameters. The wide intersubject variation in parameters supports the notion that glucose-insulin models and thus insulin delivery algorithms for people with T1DM should be personalized. This experimental protocol could be used to refine estimates of the correction factor and the insulin-to-carbohydrate ratio used by people with T1DM.
Authors: N Wake; A Hisashige; T Katayama; H Kishikawa; Y Ohkubo; M Sakai; E Araki; M Shichiri Journal: Diabetes Res Clin Pract Date: 2000-06 Impact factor: 5.602
Authors: Malgorzata E Wilinska; Ludovic J Chassin; Helga C Schaller; Lukas Schaupp; Thomas R Pieber; Roman Hovorka Journal: IEEE Trans Biomed Eng Date: 2005-01 Impact factor: 4.538