Alignment of cryo-electron tomography datasets.

Fernando Amat1, Daniel Castaño-Diez, Albert Lawrence, Farshid Moussavi, Hanspeter Winkler, Mark Horowitz.   

Abstract

Data acquisition of cryo-electron tomography (CET) samples described in previous chapters involves relatively imprecise mechanical motions: the tilt series has shifts, rotations, and several other distortions between projections. Alignment is the procedure of correcting for these effects in each image and requires the estimation of a projection model that describes how points from the sample in three-dimensions are projected to generate two-dimensional images. This estimation is enabled by finding corresponding common features between images. This chapter reviews several software packages that perform alignment and reconstruction tasks completely automatically (or with minimal user intervention) in two main scenarios: using gold fiducial markers as high contrast features or using relevant biological structures present in the image (marker-free). In particular, we emphasize the key decision points in the process that users should focus on in order to obtain high-resolution reconstructions.
Copyright © 2010 Elsevier Inc. All rights reserved.

Mesh:

Year:  2010        PMID: 20888968     DOI: 10.1016/S0076-6879(10)82014-2

Source DB:  PubMed          Journal:  Methods Enzymol        ISSN: 0076-6879            Impact factor:   1.600


  9 in total

1.  Marker-free dual-axis tilt series alignment.

Authors:  Hanspeter Winkler; Kenneth A Taylor
Journal:  J Struct Biol       Date:  2013-02-19       Impact factor: 2.867

2.  Electron tomography of paracrystalline 2D arrays.

Authors:  Hanspeter Winkler; Shenping Wu; Kenneth A Taylor
Journal:  Methods Mol Biol       Date:  2013

3.  Automatic alignment and reconstruction of images for soft X-ray tomography.

Authors:  Dilworth Y Parkinson; Christian Knoechel; Chao Yang; Carolyn A Larabell; Mark A Le Gros
Journal:  J Struct Biol       Date:  2011-12-02       Impact factor: 2.867

4.  SNARE and regulatory proteins induce local membrane protrusions to prime docked vesicles for fast calcium-triggered fusion.

Authors:  Tanmay A M Bharat; Jörg Malsam; Wim J H Hagen; Andrea Scheutzow; Thomas H Söllner; John A G Briggs
Journal:  EMBO Rep       Date:  2014-02-03       Impact factor: 8.807

5.  Relative merits and limiting factors for x-ray and electron microscopy of thick, hydrated organic materials.

Authors:  Ming Du; Chris Jacobsen
Journal:  Ultramicroscopy       Date:  2017-10-07       Impact factor: 2.689

6.  Fast Projection Matching for X-ray Tomography.

Authors:  Chun-Chieh Wang; Cheng-Cheng Chiang; Biqing Liang; Gung-Chian Yin; Yi-Tse Weng; Liang-Chi Wang
Journal:  Sci Rep       Date:  2017-06-16       Impact factor: 4.379

7.  Cryo-tomography tilt-series alignment with consideration of the beam-induced sample motion.

Authors:  Jose-Jesus Fernandez; Sam Li; Tanmay A M Bharat; David A Agard
Journal:  J Struct Biol       Date:  2018-02-03       Impact factor: 2.867

8.  Rapid alignment of nanotomography data using joint iterative reconstruction and reprojection.

Authors:  Doğa Gürsoy; Young P Hong; Kuan He; Karl Hujsak; Seunghwan Yoo; Si Chen; Yue Li; Mingyuan Ge; Lisa M Miller; Yong S Chu; Vincent De Andrade; Kai He; Oliver Cossairt; Aggelos K Katsaggelos; Chris Jacobsen
Journal:  Sci Rep       Date:  2017-09-18       Impact factor: 4.379

9.  Nanofabrication of a gold fiducial array on specimen support for electron tomography.

Authors:  Roman I Koning; Vladimir G Kutchoukov; Cornelis W Hagen; Abraham J Koster
Journal:  Ultramicroscopy       Date:  2013-07-16       Impact factor: 2.689

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.