Literature DB >> 20884972

Stress-shielding of the proximal femur using an extensively porous-coated femoral component without allograft in revision surgery: a 5- to 17-year follow-up study.

E Garcia-Cimbrelo1, E Garcia-Rey, A Cruz-Pardos, R Madero.   

Abstract

Revision surgery of the hip was performed on 114 hips using an extensively porous-coated femoral component. Of these, 95 hips (94 patients) had a mean follow-up of 10.2 years (5 to 17). No cortical struts were used and the cortical index and the femoral cortical width were measured at different levels. There were two revisions for aseptic loosening. Survivorship at 12 years for all causes of failure was 96.9% (95% confidence interval 93.5 to 100) in the best-case scenario. Fibrous or unstable fixation was associated with major bone defects. The cortical index (p = 0.045) and the lateral cortical thickness (p = 0.008) decreased at the proximal level over time while the medial cortex increased (p = 0.001) at the proximal and distal levels. An increase in the proximal medial cortex was found in patients with an extended transtrochanteric osteotomy (p = 0.026) and in those with components shorter than 25 cm (p = 0.008). The use of the extensively porous-coated femoral component can provide a solution for difficult cases in revision surgery. Radiological bony ingrowth is common. Although without clinical relevance at the end of follow-up, the thickness of the medial femoral cortex often increased while that of the lateral cortex decreased. In cases in which a shorter component was used and in those undertaken using an extended trochanteric osteotomy, there was a greater increase in thickness of the femoral cortex over time.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20884972     DOI: 10.1302/0301-620X.92B10.24317

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Increase of cortical bone after a cementless long stem in periprosthetic fractures.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos; Rosário Madero
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

2.  Medium-term outcomes of the S-ROM modular femoral stem in revision hip replacement.

Authors:  Jesús Moreta; Iker Uriarte; Xabier Foruria; Ane Loroño; Urko Agirre; Iñaki Jáuregui; José Luis Martínez-de Los Mozos
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-04-25

3.  High survival of modular tapered stems for proximal femoral bone defects at 5 to 10 years followup.

Authors:  Andrew P Van Houwelingen; Clive P Duncan; Bassam A Masri; Nelson V Greidanus; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

4.  Proximal Femoral Bone Regeneration After an Uncemented Hydroxyapatite-coated Long-stem in Revision Hip Surgery.

Authors:  José Cordero-Ampuero; Eduardo Garcia-Rey; Eduardo Garcia-Cimbrelo
Journal:  Open Orthop J       Date:  2018-03-30

5.  Correlation between the bone mineral density and stress on femur around a Duetto SI stem.

Authors:  Rina Sakai; Takeaki Yamamoto; Katsufumi Uchiyama; Kentaro Uchida; Masaki Nakao; Kiyoshi Mabuchi
Journal:  ScientificWorldJournal       Date:  2014-06-26

6.  Minimum 8-year follow-up of revision THA with severe femoral bone defects using extensively porous-coated stems and cortical strut allografts.

Authors:  Zi-Chuan Ding; Ting-Xian Ling; Ming-Cheng Yuan; Yong-Zhi Qin; Ping Mou; Hao-Yang Wang; Zong-Ke Zhou
Journal:  BMC Musculoskelet Disord       Date:  2020-04-08       Impact factor: 2.362