Literature DB >> 20883832

Bioactive Ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments.

Deepak K Pattanayak1, A Fukuda, T Matsushita, M Takemoto, S Fujibayashi, K Sasaki, N Nishida, T Nakamura, T Kokubo.   

Abstract

Selective laser melting (SLM) is a useful technique for preparing three-dimensional porous bodies with complicated internal structures directly from titanium (Ti) powders without any intermediate processing steps, with the products being expected to be useful as a bone substitute. In this study the necessary SLM processing conditions to obtain a dense product, such as the laser power, scanning speed, and hatching pattern, were investigated using a Ti powder of less than 45 μm particle size. The results show that a fully dense plate thinner than 1.8 mm was obtained when the laser power to scanning speed ratio was greater than 0.5 and the hatch spacing was less than the laser diameter, with a 30 μm thick powder layer. Porous Ti metals with structures analogous to human cancellous bone were fabricated and the compressive strength measured. The compressive strength was in the range 35-120 MPa when the porosity was in the range 75-55%. Porous Ti metals fabricated by SLM were heat-treated at 1300 °C for 1h in an argon gas atmosphere to smooth the surface. Such prepared specimens were subjected to NaOH, HCl, and heat treatment to provide bioactivity. Field emission scanning electron micrographs showed that fine networks of titanium oxide were formed over the whole surface of the porous body. These treated porous bodies formed bone-like apatite on their surfaces in a simulated body fluid within 3 days. In vivo studies showed that new bone penetrated into the pores and directly bonded to the walls within 12 weeks after implantation into the femur of Japanese white rabbits. The percentage bone affinity indices of the chemical- and heat-treated porous bodies were significantly higher than that of untreated implants.
Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20883832     DOI: 10.1016/j.actbio.2010.09.034

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  39 in total

1.  Oxidative stress and antioxidant responses of liver and kidney tissue after implantation of titanium or titanium oxide coated plate in rat tibiae.

Authors:  Nahla S El-Shenawy; Q Mohsen; Sahar A Fadl-allah
Journal:  J Mater Sci Mater Med       Date:  2012-05-17       Impact factor: 3.896

Review 2.  Properties of open-cell porous metals and alloys for orthopaedic applications.

Authors:  Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2013-07-13       Impact factor: 3.896

Review 3.  Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants.

Authors:  Eric Alexander Lewallen; Scott M Riester; Carolina A Bonin; Hilal Maradit Kremers; Amel Dudakovic; Sanjeev Kakar; Robert C Cohen; Jennifer J Westendorf; David G Lewallen; Andre J van Wijnen
Journal:  Tissue Eng Part B Rev       Date:  2014-12-18       Impact factor: 6.389

4.  Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating.

Authors:  J E Biemond; G Hannink; N Verdonschot; P Buma
Journal:  J Mater Sci Mater Med       Date:  2012-12-21       Impact factor: 3.896

Review 5.  Selective laser sintering in biomedical engineering.

Authors:  Alida Mazzoli
Journal:  Med Biol Eng Comput       Date:  2012-12-19       Impact factor: 2.602

6.  Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area.

Authors:  Mitsuru Takemoto; Shunsuke Fujibayashi; Eigo Ota; Bungo Otsuki; Hiroaki Kimura; Takeshi Sakamoto; Toshiyuki Kawai; Tohru Futami; Kiyoyuki Sasaki; Tomiharu Matsushita; Takashi Nakamura; Masashi Neo; Shuich Matsuda
Journal:  Eur Spine J       Date:  2015-03-29       Impact factor: 3.134

7.  The effect of surface topography and porosity on the tensile fatigue of 3D printed Ti-6Al-4V fabricated by selective laser melting.

Authors:  Cambre N Kelly; Nathan T Evans; Cameron W Irvin; Savita C Chapman; Ken Gall; David L Safranski
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-09       Impact factor: 7.328

8.  Use of 3D Printed Bone Plate in Novel Technique to Surgically Correct Hallux Valgus Deformities.

Authors:  Kathryn E Smith; Kenneth M Dupont; David L Safranski; Jeremy Blair; Dawn Buratti; Vladimir Zeetser; Ryan Callahan; Jason Lin; Ken Gall
Journal:  Tech Orthop       Date:  2016-09

9.  Additive manufacturing of biomaterials.

Authors:  Susmita Bose; Dongxu Ke; Himanshu Sahasrabudhe; Amit Bandyopadhyay
Journal:  Prog Mater Sci       Date:  2017-08-26

10.  Osteoconduction of porous Ti metal enhanced by acid and heat treatments.

Authors:  Toshiyuki Kawai; Mitsuru Takemoto; Shunsuke Fujibayashi; Haruhiko Akiyama; Seiji Yamaguchi; Deepak K Pattanayak; Kenji Doi; Tomiharu Matsushita; Takashi Nakamura; Tadashi Kokubo; Shuichi Matsuda
Journal:  J Mater Sci Mater Med       Date:  2013-03-27       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.