Literature DB >> 20883502

Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC, Glidescope vs the Macintosh laryngoscope for tracheal intubation.

W H L Teoh1, S Saxena, M K Shah, A T H Sia.   

Abstract

We compared the intubating characteristics of the Pentax Airway Scope, the C-MAC and the Glidescope with those of the Macintosh laryngoscope in 400 patients without predictors of difficult intubation. We found shorter intubation times with the Airway Scope (mean (SD) 20.6 (11.5) s) compared with the C-MAC (31.9 (17.6) s) and Glidescope (31.2 (15.0) s), p < 0.001. The median (IQR [range]) score for ease of intubation was significantly lower (better) with the Airway Scope (0 (0-8.75 [0-60])) than with the C-MAC (10 (0-20 [0-90])) or Glidescope (0 (0-20 [0-80])), p < 0.001. Ease of blade insertion in the C-MAC (0 (0-0 [0-30])) was superior to that of the Airway Scope (0 (0-0 [0-70])), Macintosh (0 (0-0 [0-80])) or Glidescope (0 (0-10 [0-60])), p = 0.006. More patients had a grade 1 laryngeal view with the Airway Scope (97%) compared with the C-MAC (87%), Glidescope (78%), or Macintosh (58%), p < 0.001. There were no grade 3 laryngeal views with the Airway Scope. The three videolaryngoscopes had comparable first attempt successful intubation rates: 95% for the Airway Scope, 93% for the C-MAC and 91% for the Glidescope.
© 2010 The Authors. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2010        PMID: 20883502     DOI: 10.1111/j.1365-2044.2010.06513.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  20 in total

1.  Assessing the efficacy of video versus direct laryngoscopy through retrospective comparison of 436 emergency intubation cases.

Authors:  Benjamen M Jones; Ankit Agrawal; Thomas E Schulte
Journal:  J Anesth       Date:  2013-06-13       Impact factor: 2.078

2.  [Rapid sequence induction and intubation in patients with risk of aspiration : Recommendations for action for practical management of anesthesia].

Authors:  C Eichelsbacher; H Ilper; R Noppens; J Hinkelbein; T Loop
Journal:  Anaesthesist       Date:  2018-06-29       Impact factor: 1.041

Review 3.  Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation.

Authors:  Jan Hansel; Andrew M Rogers; Sharon R Lewis; Tim M Cook; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2022-04-04

4.  A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department.

Authors:  Jarrod Mosier; Stephen Chiu; Asad E Patanwala; John C Sakles
Journal:  Ann Emerg Med       Date:  2013-01-30       Impact factor: 5.721

5.  Video Versus Direct Laryngoscopy for Inpatient Emergency Intubation in Adults.

Authors:  Tanja Rombey; Mark Schieren; Dawid Pieper
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

Review 6.  Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation.

Authors:  Sharon R Lewis; Andrew R Butler; Joshua Parker; Tim M Cook; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2016-11-15

7.  Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial.

Authors:  Jie Yi; Yahong Gong; Xiang Quan; Yuguang Huang
Journal:  BMC Anesthesiol       Date:  2015-04-28       Impact factor: 2.217

8.  A systematic review of the role of videolaryngoscopy in successful orotracheal intubation.

Authors:  David W Healy; Oana Maties; David Hovord; Sachin Kheterpal
Journal:  BMC Anesthesiol       Date:  2012-12-14       Impact factor: 2.217

9.  Predictors of difficult intubation when using a videolaryngoscope with an intermediate-angled blade during the first attempt: a prospective observational study.

Authors:  Hye Jin Kim; Hye Rim Kim; So Yeon Kim; Ha Yan Kim; Wyun Kon Park; Min Ho Lee; Hyun Joo Kim
Journal:  J Clin Monit Comput       Date:  2021-07-12       Impact factor: 1.977

10.  Awake tracheal intubation using Pentax airway scope in 30 patients: A Case series.

Authors:  Payal Kajekar; Cyprian Mendonca; Rati Danha; Carl Hillermann
Journal:  Indian J Anaesth       Date:  2014-07
View more