Literature DB >> 20878764

Efficient implementation of hardware-optimized gradient sequences for real-time imaging.

J Andrew Derbyshire1, Daniel A Herzka, Elliot R McVeigh, Robert J Lederman.   

Abstract

This work improves the performance of interactive real-time imaging with balanced steady-state free precession. The method employs hardware-optimized gradient pulses, together with a novel phase-encoding strategy that simplifies the design and implementation of the optimized gradient waveforms. In particular, the waveforms for intermediate phase-encode steps are obtained by simple linear combination, rather than separate optimized waveform calculations. Gradient waveforms are redesigned in real time as the scan plane is manipulated, and the resulting sequence operates at the specified limits of the MRI gradient subsystem for each new scan-plane orientation. The implementation provides 14-25% improvement in the sequence pulse repetition time over the vendor-supplied interactive real-time imaging sequence for similar scan parameters on our MRI scanner.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20878764      PMCID: PMC3399692          DOI: 10.1002/mrm.22211

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Minimizing dead-periods in flow-encoded or -compensated pulse sequences while imaging in oblique planes.

Authors:  B D Bolster; E Atalar
Journal:  J Magn Reson Imaging       Date:  1999-08       Impact factor: 4.813

2.  Interventional cardiovascular procedures guided by real-time MR imaging: an interactive interface using multiple slices, adaptive projection modes and live 3D renderings.

Authors:  Michael A Guttman; Cenghizhan Ozturk; Amish N Raval; Venkatesh K Raman; Alexander J Dick; Ranil DeSilva; Parag Karmarkar; Robert J Lederman; Elliot R McVeigh
Journal:  J Magn Reson Imaging       Date:  2007-12       Impact factor: 4.813

3.  Interactive coronary MRI.

Authors:  C J Hardy; R D Darrow; J M Pauly; A B Kerr; C L Dumoulin; B S Hu; K M Martin
Journal:  Magn Reson Med       Date:  1998-07       Impact factor: 4.668

4.  Real-time interactive MRI on a conventional scanner.

Authors:  A B Kerr; J M Pauly; B S Hu; K C Li; C J Hardy; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

5.  MR fluoroscopy: technical feasibility.

Authors:  S J Riederer; T Tasciyan; F Farzaneh; J N Lee; R C Wright; R J Herfkens
Journal:  Magn Reson Med       Date:  1988-09       Impact factor: 4.668

6.  Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

Authors:  E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

  6 in total
  3 in total

1.  Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

Authors:  Liheng Guo; J Andrew Derbyshire; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2015-10-31       Impact factor: 4.668

2.  Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging.

Authors:  Liheng Guo; Daniel A Herzka
Journal:  J Cardiovasc Magn Reson       Date:  2019-04-18       Impact factor: 5.364

3.  A gradient optimization toolbox for general purpose time-optimal MRI gradient waveform design.

Authors:  Michael Loecher; Matthew J Middione; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2020-07-07       Impact factor: 4.668

  3 in total