Literature DB >> 20878763

Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues.

Mario Ries1, Baudouin Denis de Senneville, Sébastien Roujol, Yasmina Berber, Bruno Quesson, Chrit Moonen.   

Abstract

Magnetic resonance imaging-guided high intensity focused ultrasound is a promising method for the noninvasive ablation of pathological tissue in abdominal organs such as liver and kidney. Due to the high perfusion rates of these organs, sustained sonications are required to achieve a sufficiently high temperature elevation to induce necrosis. However, the constant displacement of the target due to the respiratory cycle render continuous ablations challenging, since dynamic repositioning of the focal point is required. This study demonstrates subsecond 3D high intensity focused ultrasound-beam steering under magnetic resonance-guidance for the real-time compensation of respiratory motion. The target is observed in 3D space by coupling rapid 2D magnetic resonance-imaging with prospective slice tracking based on pencil-beam navigator echoes. The magnetic resonance-data is processed in real-time by a computationally efficient reconstruction pipeline, which provides the position, the temperature and the thermal dose on-the-fly, and which feeds corrections into the high intensity focused ultrasound-ablator. The effect of the residual update latency is reduced by using a 3D Kalman-predictor for trajectory anticipation. The suggested method is characterized with phantom experiments and verified in vivo on porcine kidney. The results show that for update frequencies of more than 10 Hz and latencies of less then 114 msec, temperature elevations can be achieved, which are comparable to static experiments.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20878763     DOI: 10.1002/mrm.22548

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Ultrasound echoes as biometric navigators.

Authors:  Benjamin M Schwartz; Nathan J McDannold
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

2.  Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry.

Authors:  Jing Yuan; Chang-Sheng Mei; Lawrence P Panych; Nathan J McDannold; Bruno Madore
Journal:  Quant Imaging Med Surg       Date:  2012

Review 3.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Velocity navigator for motion compensated thermometry.

Authors:  Florian Maier; Axel J Krafft; Joshua P Yung; R Jason Stafford; Andrew Elliott; Rüdiger Dillmann; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2011-03-04       Impact factor: 2.310

5.  Breath-hold MR-HIFU hyperthermia: phantom and in vivo feasibility.

Authors:  Chenchen Bing; Bingbing Cheng; Robert M Staruch; Joris Nofiele; Michelle Wodzak Staruch; Debra Szczepanski; Alan Farrow-Gillespie; Adeline Yang; Theodore W Laetsch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2019       Impact factor: 3.914

6.  Elasticity mapping of murine abdominal organs in vivo using harmonic motion imaging (HMI).

Authors:  Thomas Payen; Carmine F Palermo; Stephen A Sastra; Hong Chen; Yang Han; Kenneth P Olive; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2016-07-12       Impact factor: 3.609

7.  Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound.

Authors:  Henrik Odéen; Nick Todd; Mahamadou Diakite; Emilee Minalga; Allison Payne; Dennis L Parker
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

8.  Dual-pathway multi-echo sequence for simultaneous frequency and T2 mapping.

Authors:  Cheng-Chieh Cheng; Chang-Sheng Mei; Jeffrey Duryea; Hsiao-Wen Chung; Tzu-Cheng Chao; Lawrence P Panych; Bruno Madore
Journal:  J Magn Reson       Date:  2016-02-04       Impact factor: 2.229

9.  An MRI-compatible platform for one-dimensional motion management studies in MRI.

Authors:  Joris Nofiele; Qing Yuan; Mohammad Kazem; Ken Tatebe; Quinn Torres; Amit Sawant; Ivan Pedrosa; Rajiv Chopra
Journal:  Magn Reson Med       Date:  2015-10-23       Impact factor: 4.668

10.  Image-guided non-invasive ultrasound liver ablation using histotripsy: feasibility study in an in vivo porcine model.

Authors:  Eli Vlaisavljevich; Yohan Kim; Steven Allen; Gabe Owens; Shawn Pelletier; Charles Cain; Kimberly Ives; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2013-05-15       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.