J Xiao1, H Zhou, L Zhao, Y Sun, S Guan, B Liu, L Kong. 1. Department of Oral and Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, 145 West Changle Rd, Xi' an 710032, People's Republic of China. xiaojianrui@gmail.com
Abstract
UNLABELLED: Hydrofluoric etching and anodized hierarchical micro/nanotextured surface titanium implant was placed in mandibles of ovariectomized sheep for 12 weeks, and it showed improved osseointegration by resonance frequency analysis (RFA), microcomputed tomography (micro-CT) evaluation, histomorphometry, and biomechanical test. INTRODUCTION: This study aimed to investigate the effects of micro/nanotextured titanium implant on osseointegration in ovariectomized (OVX) sheep. METHODS: The hierarchical micro/nanotextured surface of titanium implant was fabricated by acid in 0.5% (w/v) hydrofluoric (HF) and anodized in HF acid electrolytes with a DC power of 20 V, and the machined surface implants with no treatment served as control group. The implants were placed in mandibles of OVX sheep, respectively. Twelve weeks after implantation, RFA, microcomputed tomography, histomorphometry, and biomechanical tests were applied to detect the osseointegration of the two groups. RESULTS: The implant stability quotient (ISQ) values, the maximum pull-out forces, and the bone-implant contact (BIC) were 65.5 ± 6.3, 490.6 ± 72.7 N, and 58.31 ± 5.79% in the micro/nanogroup and 58.3 ± 8.9, 394.5 ± 54.5 N, and 46.85 ± 5.04% in the control group, respectively. There was no significant difference between the two groups in ISQ values (p > 0.05), but in the micro/nanogroup, the maximal pull-out force and the BIC were increased significantly (p < 0.05 or p < 0.01). Micro-CT analysis showed that the bone volume ratio and the trabecular number increased significantly (p < 0.01), and the trabecular separation decreased significantly (p < 0.05) in the micro/nanogroup. CONCLUSION: Implant modification by HF acid etching and anodization to form a hierarchical micro/nanotextured surface could improve titanium implant osseointegration in OVX sheep 12 weeks after implantation.
UNLABELLED: Hydrofluoric etching and anodized hierarchical micro/nanotextured surface titanium implant was placed in mandibles of ovariectomized sheep for 12 weeks, and it showed improved osseointegration by resonance frequency analysis (RFA), microcomputed tomography (micro-CT) evaluation, histomorphometry, and biomechanical test. INTRODUCTION: This study aimed to investigate the effects of micro/nanotextured titanium implant on osseointegration in ovariectomized (OVX) sheep. METHODS: The hierarchical micro/nanotextured surface of titanium implant was fabricated by acid in 0.5% (w/v) hydrofluoric (HF) and anodized in HF acid electrolytes with a DC power of 20 V, and the machined surface implants with no treatment served as control group. The implants were placed in mandibles of OVX sheep, respectively. Twelve weeks after implantation, RFA, microcomputed tomography, histomorphometry, and biomechanical tests were applied to detect the osseointegration of the two groups. RESULTS: The implant stability quotient (ISQ) values, the maximum pull-out forces, and the bone-implant contact (BIC) were 65.5 ± 6.3, 490.6 ± 72.7 N, and 58.31 ± 5.79% in the micro/nanogroup and 58.3 ± 8.9, 394.5 ± 54.5 N, and 46.85 ± 5.04% in the control group, respectively. There was no significant difference between the two groups in ISQ values (p > 0.05), but in the micro/nanogroup, the maximal pull-out force and the BIC were increased significantly (p < 0.05 or p < 0.01). Micro-CT analysis showed that the bone volume ratio and the trabecular number increased significantly (p < 0.01), and the trabecular separation decreased significantly (p < 0.05) in the micro/nanogroup. CONCLUSION: Implant modification by HF acid etching and anodization to form a hierarchical micro/nanotextured surface could improve titanium implant osseointegration in OVX sheep 12 weeks after implantation.
Authors: D M Rivera-Chacon; M Alvarado-Velez; C Y Acevedo-Morantes; S P Singh; E Gultepe; D Nagesha; S Sridhar; J E Ramirez-Vick Journal: J Biomed Nanotechnol Date: 2013-06 Impact factor: 4.099
Authors: Jarkko J P Jaatinen; Rami K Korhonen; Alpo Pelttari; Heikki J Helminen; Hannu Korhonen; Reijo Lappalainen; Heikki Kröger Journal: Acta Orthop Date: 2011-04-20 Impact factor: 3.717
Authors: Carolin Gabler; Carmen Zietz; Richard Bieck; Rebecca Göhler; Tobias Lindner; Maximilian Haenle; Birgit Finke; Jürgen Meichsner; Holger Testrich; Mathias Nowottnick; Bernhard Frerich; Rainer Bader Journal: Biomed Res Int Date: 2015-04-30 Impact factor: 3.411
Authors: Laila Damiati; Marcus G Eales; Angela H Nobbs; Bo Su; Penelope M Tsimbouri; Manuel Salmeron-Sanchez; Matthew J Dalby Journal: J Tissue Eng Date: 2018-08-02 Impact factor: 7.813
Authors: Maria R Katunar; Andrea Gomez Sanchez; Josefina Ballarre; Matias Baca; Carlos Vottola; Juan C Orellano; Hanna Schell; Gustavo Duffo; Silvia Cere Journal: Prog Biomater Date: 2014-06-11