Literature DB >> 14714838

Implant treatment in the edentulous mandible: a prospective study on Brånemark system implants over more than 20 years.

Jan-Anders Ekelund1, Lars W Lindquist, Gunnar E Carlsson, Torsten Jemt.   

Abstract

PURPOSE: This prospective investigation studied the clinical and radiographic performance of mandibular fixed prostheses supported by osseointegrated implants over more than 20 years.
MATERIALS AND METHODS: A total of 273 standard Brånemark implants (10 mm long) were placed in 47 patients between 1978 and 1982. Clinical and radiographic data collected at several examinations over the 20-year observation period have been reported previously. This study presents the outcome of the latest follow-up after 20 to 23 years.
RESULTS: Thirty patients (64%; 75% of those still alive) attended the 20-year follow-up examination. Three implants were lost during the entire observation period, and the 20-year implant cumulative survival rate was 98.9%. All patients had continuous prosthesis function, but two had their mandibular prostheses remade during the 20 years. No implants or prostheses were lost or fractured during the last 5 years, and only a few prosthodontic complications were noted. The mean bone level was 1.6 mm (SD 0.90) below the reference point after 20 years, and mean bone loss was 0.2 mm (SD 0.22) between the 15- and 20-year follow-ups. Thirty-seven implants (24%) showed more than two exposed threads at the 15-year follow-up examination, but only four implants (3%) presented pain and/or bone loss exceeding one thread (0.6 mm) during the last 5 years.
CONCLUSION: The successful treatment result after 15 years continued up to more than 20 years in function. During the last 5 years, a majority of the implants with several exposed implant threads could be maintained without any complications, and the frequency of implants showing signs of ongoing peri-implantitis was less than 3%.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14714838

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  35 in total

1.  The effect of hierarchical micro/nanosurface titanium implant on osseointegration in ovariectomized sheep.

Authors:  J Xiao; H Zhou; L Zhao; Y Sun; S Guan; B Liu; L Kong
Journal:  Osteoporos Int       Date:  2010-09-29       Impact factor: 4.507

2.  Load bearing capacity of bone anchored fiber-reinforced composite device.

Authors:  Ahmed Mansour Ballo; Lippo V Lassila; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

Review 3.  Dental occlusion: modern concepts and their application in implant prosthodontics.

Authors:  Gunnar E Carlsson
Journal:  Odontology       Date:  2009-01-29       Impact factor: 2.634

4.  Mechanical analysis of prosthetic bars and dental implants in 3 and 4 implant-supported overdenture protocols using finite element analysis.

Authors:  Luiz Bassi-Junior; Rafael Oliveira de Souza Silva; Victor Hugo Dias Dos Santos; Abner da Rocha Lourenço; Paulo Vinicius Trevizoli; Hugo Gaêta-Araujo; Polyane Mazucatto Queiroz; Vilmar Divanir Gottardo
Journal:  J Oral Biol Craniofac Res       Date:  2021-05-15

5.  Laser micro-grooved, Arginine-Glycine-Apspartic acid (RGD) coated dental implants, a 5 years radiographic follow-up.

Authors:  Mohamed Ahmed Alkhodary
Journal:  Int J Health Sci (Qassim)       Date:  2014-10

Review 6.  Significance of osteoporosis in craniomaxillofacial surgery: a review of the literature.

Authors:  B Hohlweg-Majert; R Schmelzeisen; B M Pfeiffer; E Schneider
Journal:  Osteoporos Int       Date:  2005-07-16       Impact factor: 4.507

7.  Comparative evaluation of soft and hard tissue changes following endosseous implant placement using flap and flapless techniques in the posterior edentulous areas of the mandible-a randomized controlled trial.

Authors:  Divya Kumar; G Sivaram; B Shivakumar; Tss Kumar
Journal:  Oral Maxillofac Surg       Date:  2018-05-05

8.  Biological response of human bone marrow stromal cells to sandblasted titanium nitride-coated implant surfaces.

Authors:  Marco Annunziata; Luigi Guida; Letizia Perillo; Raffaella Aversa; Irene Passaro; Adriana Oliva
Journal:  J Mater Sci Mater Med       Date:  2008-07-16       Impact factor: 3.896

9.  A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Authors:  Małgorzata Idzior-Haufa; Agnieszka A Pilarska; Wiesław Hędzelek; Piotr Boniecki; Krzysztof Pilarski; Barbara Dorocka-Bobkowska
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

10.  Fabrication and in vitro release behavior of a novel antibacterial coating containing halogenated furanone-loaded poly(L-lactic acid) nanoparticles on microarc-oxidized titanium.

Authors:  Yicheng Cheng; Jiang Wu; Bo Gao; Xianghui Zhao; Junyan Yao; Shenglin Mei; Liang Zhang; Huifang Ren
Journal:  Int J Nanomedicine       Date:  2012-11-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.