Literature DB >> 15017309

Examination of the bone-implant interface in experimentally induced osteoporotic bone.

Peter Cho1, G B Schneider, Kenneth Krizan, J C Keller.   

Abstract

The objective of this study was to explore the hypothesis that osteoporotic-like (OP) conditions have a negative effect on osseointegration (OI) of dental implants. Using an ovariectomized (OVX) rat model, the extent of OI using histologic and histomorphometric analysis (HMA) under a variety of OVX conditions was assessed. Five experimental groups (n = 7 rats per group) were used: 1) OP control, 2) OI control, () OI followed by OVX treatment to induce OP (OI-->OP), 4) OP induction followed by OI (OP-->OI), and 5) OP induction simultaneously with OI (OI = OP). Using undecalcified plastic-embedded cross-sections of the implant site, HMA was performed to determine the percent of bone contact (BC) at the implant-tissue interface and percent of bone area (BA) immediately (1.5-mm diameter) surrounding the implant site. The presence of Bone Sialoprotein (BSP), an important extracellular matrix component of bone, was evaluated using immunohistochemical staining procedures. The implant control resulted in the highest level of OI (BC = 79%; BA = 87%), whereas all groups in which OVX was performed resulted in a significant reduction in BA (70-75%). High levels of BC were observed in established OP conditions (OP-->OI; BC = 79%); however, following OI, induction of OP conditions (OI-->OP) led to a significant reduction in BC (50%). In each of the OP treatment groups, a diminution of cortical bone, increased trabecularization of the host bone site, and loss of staining of BSP was observed. The results of this work indicate that although OI is possible under a variety of OP-like conditions simulating implant placement, the long-term biomechanical stability of implants under these conditions could be compromised and remains unclear. Further research to understand implant use in the complex bone environment under OP-like conditions is encouraged.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15017309     DOI: 10.1097/01.id.0000116456.76235.bc

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  14 in total

1.  The effect of hierarchical micro/nanosurface titanium implant on osseointegration in ovariectomized sheep.

Authors:  J Xiao; H Zhou; L Zhao; Y Sun; S Guan; B Liu; L Kong
Journal:  Osteoporos Int       Date:  2010-09-29       Impact factor: 4.507

2.  Comparative study of axial and femoral bone mineral density and parameters of mandibular bone quality in patients receiving dental implants.

Authors:  M A L Amorim; L Takayama; V Jorgetti; R M R Pereira
Journal:  Osteoporos Int       Date:  2006-06-24       Impact factor: 4.507

3.  Implants of polyanionic collagen matrix in bone defects of ovariectomized rats.

Authors:  Marcelo Rodrigues Cunha; Arnaldo Rodrigues Santos; Gilberto Goissis; Selma C Genari
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

4.  Impact of osteoporosis in dental implants: A systematic review.

Authors:  Gabriela Giro; Leandro Chambrone; Abrao Goldstein; Jose Augusto Rodrigues; Elton Zenóbio; Magda Feres; Luciene Cristina Figueiredo; Alessandra Cassoni; Jamil Awad Shibli
Journal:  World J Orthop       Date:  2015-03-18

5.  Influence of estrogen deficiency on bone around osseointegrated dental implants: an experimental study in the rat jaw model.

Authors:  Gabriela Giro; Paulo G Coelho; Roberto Sales-Pessoa; Rosa Maria Rodrigues Pereira; Toshihisa Kawai; Silvana Regina Perez Orrico
Journal:  J Oral Maxillofac Surg       Date:  2011-04-29       Impact factor: 1.895

Review 6.  Pharmacologic augmentation of implant fixation in osteopenic bone.

Authors:  R D Ross; J L Hamilton; B M Wilson; D R Sumner; A S Virdi
Journal:  Curr Osteoporos Rep       Date:  2014-03       Impact factor: 5.096

7.  Efficacy of proline in the treatment of menopause.

Authors:  Sun-Young Nam; Myoung-Schook Yoou; Hyung-Min Kim; Hyun-Ja Jeong
Journal:  Exp Biol Med (Maywood)       Date:  2016-01-31

8.  Comparative study of axial and femoral bone mineral density and parameters of mandibular bone quality in patients receiving dental implants.

Authors:  M A L Amorim; L Takayama; V Jorgetti; R M R Pereira
Journal:  Osteoporos Int       Date:  2007-05       Impact factor: 4.507

9.  Treatment of eggshell with casein phosphopeptide reduces the severity of ovariectomy-induced bone loss.

Authors:  Jung-Hoon Kim; Min Seuk Kim; Hong-Geun Oh; Hak-Yong Lee; Jeong-Woo Park; Bong-Gun Lee; Sang-Hoon Park; Dae-In Moon; Eun-Hye Shin; Eun-Kyeong Oh; Munkhsoyol Erkhembaatar; Okjin Kim; Yong-Rae Lee; Han-Jung Chae
Journal:  Lab Anim Res       Date:  2013-06-24

10.  Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.

Authors:  José L Calvo-Guirado; Antonio Aguilar-Salvatierra; Javier Guardia; Rafael Delgado-Ruiz; María P Ramírez-Fernández; Cristina Pérez Sánchez; Gerardo Gómez-Moreno
Journal:  J Clin Exp Dent       Date:  2012-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.