Literature DB >> 20876029

Design and testing of an advanced implantable neuroprosthesis with myoelectric control.

Ronald L Hart1, Niloy Bhadra, Fred W Montague, Kevin L Kilgore, P Hunter Peckham.   

Abstract

An implantable stimulator-telemeter (IST-12) was developed for applications in neuroprosthetic restoration of limb function in paralyzed individuals. The IST-12 provides 12 stimulation channels and two myoelectric signal (MES) channels. The MES circuitry includes a two-channel multiplexer, preamplifier, variable gain amplifier/bandpass filter, full-wave rectifier, and bin integrator. Power and control signals are transmitted from an external control unit to the IST-12 through an inductive link. Recorded MES signals are telemetered back to the external control unit through the same inductive link. Following bench testing, one device was implanted chronically in a dog for 15 months and evaluated. Conditions were identified in which MES could be recorded with minimal stimulus artifact. The ability to record MES in the presence of stimulation was verified, confirming the potential of the IST-12 to be used as a myoelectric controlled neuroprosthesis.

Entities:  

Mesh:

Year:  2010        PMID: 20876029     DOI: 10.1109/TNSRE.2010.2079952

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  13 in total

1.  Multi-muscle FES force control of the human arm for arbitrary goals.

Authors:  Eric M Schearer; Yu-Wei Liao; Eric J Perreault; Matthew C Tresch; William D Memberg; Robert F Kirsch; Kevin M Lynch
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2013-10-07       Impact factor: 3.802

Review 2.  Functional electrical stimulation and spinal cord injury.

Authors:  Chester H Ho; Ronald J Triolo; Anastasia L Elias; Kevin L Kilgore; Anthony F DiMarco; Kath Bogie; Albert H Vette; Musa L Audu; Rudi Kobetic; Sarah R Chang; K Ming Chan; Sean Dukelow; Dennis J Bourbeau; Steven W Brose; Kenneth J Gustafson; Zelma H T Kiss; Vivian K Mushahwar
Journal:  Phys Med Rehabil Clin N Am       Date:  2014-08       Impact factor: 1.784

3.  Implanted neuroprosthesis for restoring arm and hand function in people with high level tetraplegia.

Authors:  William D Memberg; Katharine H Polasek; Ronald L Hart; Anne M Bryden; Kevin L Kilgore; Gregory A Nemunaitis; Harry A Hoyen; Michael W Keith; Robert F Kirsch
Journal:  Arch Phys Med Rehabil       Date:  2014-02-20       Impact factor: 3.966

4.  A preliminary comparison of myoelectric and cyclic control of an implanted neuroprosthesis to modulate gait speed in incomplete SCI.

Authors:  Lisa M Lombardo; Stephanie N Bailey; Kevin M Foglyano; Michael E Miller; Gilles Pinault; Ronald J Triolo
Journal:  J Spinal Cord Med       Date:  2014-09-22       Impact factor: 1.985

5.  Holding Static Arm Configurations With Functional Electrical Stimulation: A Case Study.

Authors:  Derek N Wolf; Eric M Schearer
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2018-08-20       Impact factor: 3.802

6.  Semiparametric Identification of Human Arm Dynamics for Flexible Control of a Functional Electrical Stimulation Neuroprosthesis.

Authors:  Eric M Schearer; Yu-Wei Liao; Eric J Perreault; Matthew C Tresch; William D Memberg; Robert F Kirsch; Kevin M Lynch
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2016-02-29       Impact factor: 3.802

7.  Implanted neuroprosthesis for assisting arm and hand function after stroke: a case study.

Authors:  Jayme S Knutson; John Chae; Ronald L Hart; Michael W Keith; Harry A Hoyen; Mary Y Harley; Terri Z Hisel; Anne M Bryden; Kevin L Kilgore; Hunter Peckham
Journal:  J Rehabil Res Dev       Date:  2012

8.  Evolution of Neuroprosthetic Approaches to Restoration of Upper Extremity Function in Spinal Cord Injury.

Authors:  Kevin L Kilgore; Anne Bryden; Michael W Keith; Harry A Hoyen; Ronald L Hart; Gregory A Nemunaitis; P Hunter Peckham
Journal:  Top Spinal Cord Inj Rehabil       Date:  2018

9.  A fully implanted intramuscular bipolar myoelectric signal recording electrode.

Authors:  William D Memberg; Thomas G Stage; Robert F Kirsch
Journal:  Neuromodulation       Date:  2014-03-10

10.  Long-Term Performance and User Satisfaction With Implanted Neuroprostheses for Upright Mobility After Paraplegia: 2- to 14-Year Follow-Up.

Authors:  Ronald J Triolo; Stephanie Nogan Bailey; Kevin M Foglyano; Rudi Kobetic; Lisa M Lombardo; Michael E Miller; Gilles Pinault
Journal:  Arch Phys Med Rehabil       Date:  2017-09-09       Impact factor: 4.060

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.