Literature DB >> 20870385

Metal backing significantly decreases tibial strains in a medial unicompartmental knee arthroplasty model.

Scott R Small1, Michael E Berend, Merrill A Ritter, Christine A Buckley, Renee D Rogge.   

Abstract

Clinical success of unicompartmental knee arthroplasty (UKA) is on the rise and is dependent on multiple patient, implant, and surgical factors. Tibial subsidence has been clinically reported as a cause of failure in UKA with an all-polyethylene tibial design in the absence of metal backing, yet the role of metal backing UKA tibial components on tibial loading is not fully understood. In this study, composite tibiae were implanted with medial all-polyethylene fixed-bearing or metal-backed UKA tibial components and a 1.5-kN load applied in 3 different contact positions simulating femoral translation during gait. All-polyethylene tibial components exhibited significantly higher strain measurements in each femoral position. This study demonstrates the role that metal backing plays on generating an even loading distribution while diminishing the development localized regions of excessive loading across the medial tibial cortex.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20870385     DOI: 10.1016/j.arth.2010.07.021

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  Surgeon's experience influences UKA survivorship: a comparative study between all-poly and metal back designs.

Authors:  F Zambianchi; V Digennaro; A Giorgini; G Grandi; F Fiacchi; R Mugnai; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-30       Impact factor: 4.342

2.  An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components.

Authors:  Alfonso Manzotti; Cesare Chemello; Chris Pullen; Pietro Cerveri; Norberto Confalonieri
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-26       Impact factor: 4.342

3.  All-polyethylene unicompartmental knee arthroplasty is associated with increased risks of poorer knee society knee score and lower satisfaction in obese patients.

Authors:  Wayne Yong Xiang Foo; Ming Han Lincoln Liow; Jerry Yongqiang Chen; Darren Keng Jin Tay; Ngai Nung Lo; Seng Jin Yeo
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-30       Impact factor: 3.067

4.  Do Fixed or Mobile Bearing Implants Have Better Survivorship in Medial Unicompartmental Knee Arthroplasty? A Study From the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Arun Kannan; Peter L Lewis; Chelsea Dyer; William A Jiranek; Stephen McMahon
Journal:  Clin Orthop Relat Res       Date:  2021-07-01       Impact factor: 4.755

5.  Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model.

Authors:  C E H Scott; M J Eaton; R W Nutton; F A Wade; S L Evans; P Pankaj
Journal:  Bone Joint Res       Date:  2017-01       Impact factor: 5.853

6.  The effect of malalignment on proximal tibial strain in fixed-bearing unicompartmental knee arthroplasty: A comparison between metal-backed and all-polyethylene components using a validated finite element model.

Authors:  I Danese; P Pankaj; C E H Scott
Journal:  Bone Joint Res       Date:  2019-03-02       Impact factor: 5.853

Review 7.  Periprosthetic fractures after medial unicompartmental knee arthroplasty: a narrative review.

Authors:  L Thoreau; D Morcillo Marfil; E Thienpont
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-15       Impact factor: 2.928

8.  The effect of implant position on bone strain following lateral unicompartmental knee arthroplasty: A Biomechanical Model Using Digital Image Correlation.

Authors:  A M Ali; S D S Newman; P A Hooper; C M Davies; J P Cobb
Journal:  Bone Joint Res       Date:  2017-08       Impact factor: 5.853

9.  Ten-year survival and patient-reported outcomes of a medial unicompartmental knee arthroplasty incorporating an all-polyethylene tibial component.

Authors:  Chloe E H Scott; Frazer A Wade; Deborah MacDonald; Richard W Nutton
Journal:  Arch Orthop Trauma Surg       Date:  2018-02-23       Impact factor: 3.067

10.  Mid-Term Outcomes of Metal-Backed Unicompartmental Knee Arthroplasty Show Superiority to All-Polyethylene Unicompartmental and Total Knee Arthroplasty.

Authors:  Jelle P van der List; Laura J Kleeblad; Hendrik A Zuiderbaan; Andrew D Pearle
Journal:  HSS J       Date:  2017-05-12
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.