Literature DB >> 15570363

In-situ quantitative analysis of a prostate-specific antigen (PSA) using a nanomechanical PZT cantilever.

Kyo Seon Hwang1, Jeong Hoon Lee, Jaebum Park, Dae Sung Yoon, Jung Ho Park, Tae Song Kim.   

Abstract

We report on a novel technique of resonant frequency shift measurement based on a nanomechanical cantilever with a PZT actuating layer for label-free detection of a prostate-specific antigen (PSA) in a liquid environment. The nanomechanical PZT thin film cantilever is composed of SiO(2)/Ta/Pt/PZT/Pt/SiO(2) on a SiN(x) supporting layer for simultaneous self-exciting and sensing; it was fabricated using a standard MEMS (micro electromechanical system) process. The specific binding characteristics of the PSA antigen to its antibody, which is immobilized with Calixcrown self-assembled monolayers (SAMs) on a gold surface deposited on a cantilever, are determined to a high sensitivity. For the bioassay in a liquid environment, a liquid test cell with a 20 microl volume reaction chamber has been fabricated, using a bonding technique between poly(dimethyl siloxane) (PDMS) bilayers. An observed trend of resonant frequency change with respect to time could be explained by the binding kinetics due to the Langmuir isotherm and diffusion and by the effects of a small volume reaction chamber. In the saturated regimes, the resonant frequency of the cantilever increased with increase of the PSA concentration in the reaction chamber, showing that the trend of the resonance frequency change was similar to that of the fluorescence results. The saturated resonance frequency shift of the cantilever was proportional to the PSA antigen concentration of analyte solution.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15570363     DOI: 10.1039/b410905h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  13 in total

1.  Low-concentration mechanical biosensor based on a photonic crystal nanowire array.

Authors:  Yuerui Lu; Songming Peng; Dan Luo; Amit Lal
Journal:  Nat Commun       Date:  2011-12-06       Impact factor: 14.919

2.  Mechanism of flexural resonance frequency shift of a piezoelectric microcantilever sensor during humidity detection.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Appl Phys Lett       Date:  2008-05-09       Impact factor: 3.791

Review 3.  Comparative advantages of mechanical biosensors.

Authors:  J L Arlett; E B Myers; M L Roukes
Journal:  Nat Nanotechnol       Date:  2011-03-27       Impact factor: 39.213

4.  Label free detection of white spot syndrome virus using lead magnesium niobate-lead titanate piezoelectric microcantilever sensors.

Authors:  Joseph A Capobianco; Wei-Heng Shih; Jiann-Horng Leu; Grace Chu-Fang Lo; Wan Y Shih
Journal:  Biosens Bioelectron       Date:  2010-08-11       Impact factor: 10.618

5.  Real-Time, Label-Free, All-Electrical Detection of Salmonella typhimurium Using Lead Zirconate Titanate/Gold-Coated Glass Cantilevers at any Relative Humidity.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2007-08-08       Impact factor: 7.460

6.  Enhanced Detection Resonance Frequency Shift of a Piezoelectric Microcantilever Sensor by a DC Bias Electric Field in Humidity Detection.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2009-04-24       Impact factor: 7.460

Review 7.  Label-free technologies for quantitative multiparameter biological analysis.

Authors:  Abraham J Qavi; Adam L Washburn; Ji-Yeon Byeon; Ryan C Bailey
Journal:  Anal Bioanal Chem       Date:  2009-02-17       Impact factor: 4.142

Review 8.  Measurement of Mechanical Properties of Cantilever Shaped Materials.

Authors:  Eric Finot; Ali Passian; Thomas Thundat
Journal:  Sensors (Basel)       Date:  2008-05-26       Impact factor: 3.576

Review 9.  Hybrid integrated label-free chemical and biological sensors.

Authors:  Simin Mehrabani; Ashley J Maker; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2014-03-26       Impact factor: 3.576

Review 10.  Integrated Resonant Micro/Nano Gravimetric Sensors for Bio/Chemical Detection in Air and Liquid.

Authors:  Hao Jia; Pengcheng Xu; Xinxin Li
Journal:  Micromachines (Basel)       Date:  2021-05-31       Impact factor: 2.891

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.