Literature DB >> 15137038

A method for interleaved acquisition of a vascular input function for dynamic contrast-enhanced MRI in experimental rat tumours.

Dominick J O McIntyre1, Christian Ludwig, Amit Pasan, John R Griffiths.   

Abstract

Dynamic contrast-enhanced MRI is widely used for the evaluation of the response of experimental rodent tumours to antitumour therapy, particularly for the newly developing antiangiogenic and antivascular agents. However, standard models require a time-course for the plasma concentration of contrast agent (usually referred to as the arterial input function) to calculate the transfer constant K(trans) from the dynamic time-course data. Ideally, the plasma concentration time-course should be measured during each experiment to obtain the most accurate measure of K(trans). This is technically difficult in rodents, so assumed values are generally used. A method is presented here using interleaved acquisitions from a tail coil to obtain the plasma concentration simultaneously with DCE-MRI data obtained from a solenoid coil around the tumour. The SNR of the resulting vascular input function data is high compared with methods using a volume coil to acquire plasma concentrations from the aorta and vena cava. Copyright 2004 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15137038     DOI: 10.1002/nbm.868

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  9 in total

1.  Incorporating the effects of transcytolemmal water exchange in a reference region model for DCE-MRI analysis: theory, simulations, and experimental results.

Authors:  Thomas E Yankeelov; Jeffrey J Luci; Laura M DeBusk; P Charles Lin; John C Gore
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

Review 2.  Dynamic contrast-enhanced magnetic resonance imaging: fundamentals and application to the evaluation of the peripheral perfusion.

Authors:  Yaron Gordon; Sasan Partovi; Matthias Müller-Eschner; Erick Amarteifio; Tobias Bäuerle; Marc-André Weber; Hans-Ulrich Kauczor; Fabian Rengier
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

3.  Fast, reproducible measurement of the vascular input function in mice using constrained reconstruction and cardiac sampling.

Authors:  Dustin K Ragan; Stephen Y Lai; James A Bankson
Journal:  NMR Biomed       Date:  2010-09-22       Impact factor: 4.044

Review 4.  Dynamic Contrast-Enhanced MR Imaging in Head and Neck Cancer: Techniques and Clinical Applications.

Authors:  S Gaddikeri; R S Gaddikeri; T Tailor; Y Anzai
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

5.  Comparison of dynamic contrast-enhanced MRI and quantitative SPECT in a rat glioma model.

Authors:  Jack T Skinner; Thomas E Yankeelov; Todd E Peterson; Mark D Does
Journal:  Contrast Media Mol Imaging       Date:  2012 Nov-Dec       Impact factor: 3.161

6.  Suppression of vascular enhancement artifacts through the use of a multiband, selectively spoiled radiofrequency excitation pulse.

Authors:  Dustin K Ragan; James A Bankson
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

7.  Use of a reference tissue and blood vessel to measure the arterial input function in DCEMRI.

Authors:  Xiaobing Fan; Chad R Haney; Devkumar Mustafi; Cheng Yang; Marta Zamora; Erica J Markiewicz; Gregory S Karczmar
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

8.  Rat tumor response to the vascular-disrupting agent 5,6-dimethylxanthenone-4-acetic acid as measured by dynamic contrast-enhanced magnetic resonance imaging, plasma 5-hydroxyindoleacetic acid levels, and tumor necrosis.

Authors:  Lesley D McPhail; Dominick J O McIntyre; Christian Ludwig; Philip Kestell; John R Griffiths; Lloyd R Kelland; Simon P Robinson
Journal:  Neoplasia       Date:  2006-03       Impact factor: 5.715

9.  Dynamic Contrast Enhanced Magnetic Resonance Imaging in Oncology: Theory, Data Acquisition, Analysis, and Examples.

Authors:  Thomas E Yankeelov; John C Gore
Journal:  Curr Med Imaging Rev       Date:  2009-05-01
  9 in total