Literature DB >> 18219632

High-resolution peripheral vein bypass graft wall studies using high sampling efficiency inner volume 3D FSE.

Dimitris Mitsouras1, Robert V Mulkern, Christopher D Owens, Michael S Conte, Hale Ersoy, Tuan M Luu, Amanda G Whitmore, Mark A Creager, Frank J Rybicki.   

Abstract

A 3D inner-volume fast spin echo (3D IV-FSE) sequence was developed for ECG-gated, black-blood, T1- and T2-weighted vessel wall imaging of peripheral vein bypass grafts (PVBG). The sequence utilizes nonselective refocusing excitations to minimize echo spacings and a highly selective IV excitation scheme to minimize the need for oversampling of z-encode slice selections. The method was tested in eight PVBG patients who also underwent 2D FSE graft imaging. High-quality 3D imaging was achieved in all subjects, with significant spatial resolution and volume coverage gains compared to the more conventional 2D FSE sequences normalized for signal-to-noise ratios (SNRs) and scan times. Compared to previously proposed 3D IV-FSE methods, nonselective refocusing resulted in a more than 20% FSE echo train sampling efficiency increase while the use of highly selective IV excitation resulted in a 30% improvement in slice oversampling efficiency. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18219632     DOI: 10.1002/mrm.21359

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

2.  Immobilized contrast-enhanced MRI: Gadolinium-based long-term MR contrast enhancement of the vein graft vessel wall.

Authors:  Dimitris Mitsouras; Praveen Kumar Vemula; Peng Yu; Ming Tao; Binh T Nguyen; Christina M Campagna; Jeffrey M Karp; Robert V Mulkern; C Keith Ozaki; Frank J Rybicki
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

3.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

Review 4.  Adaptive changes in autogenous vein grafts for arterial reconstruction: clinical implications.

Authors:  Christopher D Owens
Journal:  J Vasc Surg       Date:  2009-10-17       Impact factor: 4.268

5.  Early animal model evaluation of an implantable contrast agent to enhance magnetic resonance imaging of arterial bypass vein grafts.

Authors:  Dimitrios Mitsouras; Ming Tao; Margreet R de Vries; Kaspar Trocha; Oscar R Miranda; Praveen Kumar Vemula; Kui Ding; Amir Imanzadeh; Frederick J Schoen; Jeffrey M Karp; C Keith Ozaki; Frank J Rybicki
Journal:  Acta Radiol       Date:  2018-01-29       Impact factor: 1.990

6.  Targeted Nanoparticle Binding to Hydroxyapatite in a High Serum Environment for Early Detection of Heart Disease.

Authors:  Cari L Meisel; Polly Bainbridge; Dimitrios Mitsouras; Joyce Y Wong
Journal:  ACS Appl Nano Mater       Date:  2018-08-21

7.  Lower extremity peripheral vein bypass graft wall thickness changes demonstrated at 1 and 6 months after surgery with ultra-high spatial resolution black blood inner volume three-dimensional fast spin echo magnetic resonance imaging.

Authors:  Frank John Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda G Whitmore; Hale Ersoy; Robert V Mulkern; Mark A Creager; Michael S Conte
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-14       Impact factor: 2.357

8.  Immobilization of iron oxide magnetic nanoparticles for enhancement of vessel wall magnetic resonance imaging--an ex vivo feasibility study.

Authors:  Binh Thai Nguyen; Praveen Kumar Vemula; Dimitrios Mitsouras; Peng Yu; Ming Tao; Christina Campagna; Robert V Mulkern; Frank J Rybicki; Jeffrey M Karp; C Keith Ozaki
Journal:  Bioconjug Chem       Date:  2010-08-18       Impact factor: 4.774

9.  Upper extremity composite tissue allotransplantation imaging.

Authors:  Elizabeth George; Dimitrios Mitsouras; Kanako K Kumamaru; Nehal Shah; Stacy E Smith; Kurt Schultz; Pamela M Deaver; Katherine M Mullen; Michael L Steigner; Edwin C Gravereaux; Shadpour Demehri; Ericka M Bueno; Simon G Talbot; Bohdan Pomahac; Frank J Rybicki
Journal:  Eplasty       Date:  2013-07-16

10.  Phase relaxed localized excitation pulses for inner volume fast spin echo imaging.

Authors:  Shaihan J Malik; Joseph V Hajnal
Journal:  Magn Reson Med       Date:  2015-10-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.