Literature DB >> 20855647

Evaluation of the Ves-Matic Cube 200 erythrocyte sedimentation method: comparison with Westergren-based methods.

Joyce Curvers1, Jurgen Kooren, Maartje Laan, Edwin van Lierop, Daan van de Kerkhof, Volkher Scharnhorst, Martien Herruer.   

Abstract

The erythrocyte sedimentation rate (ESR) is still a widely used parameter for acute phase inflammation. Recently, new methods based on direct undiluted measurement of ESR in a standard EDTA tube have been developed. We evaluated the analytic performance of one of these new methods, the Ves-Matic Cube 200 (Diesse Diagnostica Senese, Siena, Italy), and compared it with several established Westergren-based diluted methods. The Ves-Matic Cube 200 showed a poor correlation (r = 0.83) with the International Council for Standardization in Haematology Westergren reference method, mainly caused by a considerable negative bias at low ESR levels. Moreover, a random bias was found at higher ESR levels that correlated with hematocrit levels, suggesting a differential influence of packed cell volume on the Ves-Matic Cube 200 results compared with Westergren results. We conclude that the Ves-Matic Cube 200 method is not interchangeable with Westergren-based diluted methods and generates ESR results that are too deviant to be clinically acceptable.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20855647     DOI: 10.1309/AJCPMEWW62BGQHJH

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  6 in total

1.  Evaluation of Ves-Matic Cube 200 for erythrocyte sedimentation rate determination.

Authors:  Sevilay Sezer; Fatma Meriç Yilmaz; Oğuzhan Kaya; Sema Uysal
Journal:  J Clin Lab Anal       Date:  2013-09       Impact factor: 2.352

2.  Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method.

Authors:  Elise Schapkaitz; Shilla RabuRabu; Marcel Engelbrecht
Journal:  J Clin Lab Anal       Date:  2018-08-26       Impact factor: 2.352

3.  Comparison of iSED and Ves-Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method.

Authors:  Nihal Boğdaycioğlu; Fatma Meric Yilmaz; Sevilay Sezer; Esra Oğuz
Journal:  J Clin Lab Anal       Date:  2014-08-17       Impact factor: 2.352

4.  Test-1 analyzer and conventional Westergren method for erythrocyte sedimentation rate: A comparative study between two laboratories.

Authors:  Cigdem Sonmez; Ozlem Ceylan Dogan; Aysegul Ozturk Kaymak; Nedim Akkaya; Kadir Okhan Akin; Gulcan Guntas
Journal:  J Clin Lab Anal       Date:  2018-01-17       Impact factor: 2.352

5.  Preoperatively elevated serum inflammatory markers increase the risk of periprosthetic joint infection following total knee arthroplasty in patients with osteoarthritis.

Authors:  Chi Xu; Heng Guo; Pengfei Qu; Jun Fu; Feng-Chih Kuo; Ji-Ying Chen
Journal:  Ther Clin Risk Manag       Date:  2018-09-17       Impact factor: 2.423

6.  Predictors of flare in rheumatoid arthritis patients with persistent clinical remission/low disease activity: Data from the TARAC cohort.

Authors:  Sumapa Chaiamnuay; Srisakul Jiemjit; Wipatcharin Songdechaphipat; Pongthorn Narongroeknawin; Rattapol Pakchotanon; Paijit Asavatanabodee
Journal:  Medicine (Baltimore)       Date:  2022-08-12       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.